Old 21st October 2007, 20:47   #11 (permalink)
New Member
 
divescot's Avatar

Current Rebreather/s:
Inspiration Classic

Other Rebreather/s:
 
Join Date: Oct 2005
Location: UK
Posts: 32
divescot is an unknown quantity at this point
Unhappy Re: about to throw VR3 brick away

OK, done all stages and millivolt reading does not change. Once unit is calibrated to 98% and I breath off the loop the reading does not change. either port is stuck on vr3 or cell has gone very wrong. so...I changed the cell and no change, still gives me the exact same mV rating, surely that can't be correct.

Going to give up for this evening and try again tomorrow.

Cheers

Mark
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 22nd October 2007, 04:23   #12 (permalink)
Custom Title Allowed!
 
Drmike's Avatar

Current Rebreather/s:
MK 15.X
Ouroboros
Other CCR
Home Build

Other Rebreather/s:
Inspiration Classic
Other CCR
Home Build
 
Join Date: Feb 2005
Posts: 3,062
Drmike has a reputation beyond reputeDrmike has a reputation beyond reputeDrmike has a reputation beyond reputeDrmike has a reputation beyond reputeDrmike has a reputation beyond reputeDrmike has a reputation beyond reputeDrmike has a reputation beyond reputeDrmike has a reputation beyond reputeDrmike has a reputation beyond reputeDrmike has a reputation beyond reputeDrmike has a reputation beyond repute
Re: about to throw VR3 brick away

why not call the factory? Ive found them to be very helpful and it would save mud slinging when most of the time the user is in error (and Im speaking from personal experience here - i hate reading instruction manuals )
__________________
Get a girlfriend you sad twat - a Rebreather is an unfaithful mistress - dont blind yourself to her faults just because she goes down on you
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 22nd October 2007, 06:31   #13 (permalink)
Closed Circuit Divers Aus
 
Lancer4545's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
 
Join Date: Jun 2007
Location: Cairns QLD Australia
Posts: 534
Lancer4545 has a spectacular aura aboutLancer4545 has a spectacular aura aboutLancer4545 has a spectacular aura aboutLancer4545 has a spectacular aura aboutLancer4545 has a spectacular aura aboutLancer4545 has a spectacular aura about
Send a message via Skype™ to Lancer4545
Re: about to throw VR3 brick away

Quote: (Originally Posted by divescot) View Original Post
OK, done all stages and millivolt reading does not change. Once unit is calibrated to 98% and I breath off the loop the reading does not change. either port is stuck on vr3 or cell has gone very wrong. so...I changed the cell and no change, still gives me the exact same mV rating, surely that can't be correct.

Going to give up for this evening and try again tomorrow.

Cheers

Mark
Hi Mark,

I have been having a similar problem with mine. No matter whether I calibrate in air or 98% there is still a difference in the PO2 reading. I dived it once and had all sorts of warnings after the PO2 reading went sky high once I was at depth, so I changed back to fixed setpoint and continued the dive without incident.

I emailled AL Wright at Deltp P and he was very helpful. After I did all the checks he suggested he then said it was best to send it back and have it checked over which I now plan to do.

I am running an earlier software version so I will get it updated at the same time.

AL Wright's email at Delta P support@vr3.co.uk

Regards,

Lance
__________________
You can run but you can't hide!

ISC Appointed Megalodon Dealer for East Australia
http://www.closedcircuitdivers.com.au
info@closedcircuitdivers.com.au

Last edited by Lancer4545 : 22nd October 2007 at 06:33. Reason: Weird formatting
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 6th January 2008, 00:01   #14 (permalink)
New Member
 
DiverDave73's Avatar

Current Rebreather/s:
rEvo

Other Rebreather/s:
rEvo
 
Join Date: May 2007
Location: Sydney
Posts: 6
DiverDave73 is an unknown quantity at this point
Re: about to throw VR3 brick away

why do you calibrate with NX98 not NX99? I was taught to use NX99.

Dave
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 6th January 2008, 04:55   #15 (permalink)
rEvo CCR Driver
 
silentscuba's Avatar

Current Rebreather/s:
Classic Kiss
rEvo

Other Rebreather/s:
Inspiration Classic
rEvo
 
Join Date: Jun 2005
Location: Mill Creek, WA USA
Posts: 566
silentscuba has a spectacular aura aboutsilentscuba has a spectacular aura aboutsilentscuba has a spectacular aura aboutsilentscuba has a spectacular aura aboutsilentscuba has a spectacular aura aboutsilentscuba has a spectacular aura about
Re: about to throw VR3 brick away

Quote: (Originally Posted by divescot) View Original Post
Dear All

What do i do now???

Do i sell and buy a pursuit?

Mark
YES !!!! if you haven't already
__________________
Curt McNamee
rEvo CCR Diver
KISS CCR Diver
www.silentscuba.com
(Online)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 6th January 2008, 06:33   #16 (permalink)
Closed Circuit Divers Aus
 
Lancer4545's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
 
Join Date: Jun 2007
Location: Cairns QLD Australia
Posts: 534
Lancer4545 has a spectacular aura aboutLancer4545 has a spectacular aura aboutLancer4545 has a spectacular aura aboutLancer4545 has a spectacular aura aboutLancer4545 has a spectacular aura aboutLancer4545 has a spectacular aura about
Send a message via Skype™ to Lancer4545
Re: about to throw VR3 brick away

An update on my dramas with the VR3 not reading the O2 analyser and 4th cell correctly.

After messing around with the settings and many attempts to get the 4th cell to read correctly I finally sent it back to have it checked over and have the software updated to V2007.

I have just had a reply from them to say the board was found to be faulty and they have replaced it free of charge. All I had to do was pay to have the software updated.

That's fantastic service in anyones language. Thanks Al and the guys at Delta P !!!

Regards,

Lance
__________________
You can run but you can't hide!

ISC Appointed Megalodon Dealer for East Australia
http://www.closedcircuitdivers.com.au
info@closedcircuitdivers.com.au
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 6th January 2008, 08:54   #17 (permalink)
Nad
Rebel to the Bone
 
Nad's Avatar

Current Rebreather/s:
Ouroboros

Other Rebreather/s:
Not Bought Yet
Inspiration Classic
 
Join Date: Mar 2005
Location: Europe
Posts: 925
Nad is a jewel in the roughNad is a jewel in the roughNad is a jewel in the roughNad is a jewel in the roughNad is a jewel in the roughNad is a jewel in the roughNad is a jewel in the roughNad is a jewel in the rough
Re: about to throw VR3 brick away

Quote: (Originally Posted by divescot) View Original Post
OK, done all stages and millivolt reading does not change. Once unit is calibrated to 98% and I breath off the loop the reading does not change. either port is stuck on vr3 or cell has gone very wrong. so...I changed the cell and no change, still gives me the exact same mV rating, surely that can't be correct.

Going to give up for this evening and try again tomorrow.

Cheers

Mark

N@90 holder should be better. With the Inspiration 4th cell adaptor the readings are sometime a bit fanny. Probably because of the position. This is why I never used it.
Just pendant and a VR3 CCR. That's it.

Nad
__________________
The Impossible is often the Untried
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 6th January 2008, 09:37   #18 (permalink)
SiegeEngine II
 
Mdemon's Avatar

Current Rebreather/s:
Inspiration Classic
Home Build

Other Rebreather/s:
Inspiration Classic
Home Build
 
Join Date: Feb 2007
Location: SWUK
Posts: 1,866
Mdemon has much to be proud ofMdemon has much to be proud ofMdemon has much to be proud ofMdemon has much to be proud ofMdemon has much to be proud ofMdemon has much to be proud ofMdemon has much to be proud ofMdemon has much to be proud ofMdemon has much to be proud ofMdemon has much to be proud ofMdemon has much to be proud of
Re: about to throw VR3 brick away

Quote: (Originally Posted by Nad) View Original Post
N@90 holder should be better. With the Inspiration 4th cell adaptor the readings are sometime a bit fanny. Probably because of the position. This is why I never used it.
Just pendant and a VR3 CCR. That's it.

Nad
Agreed. Also, O2-flush three times when calibrating the VR£ in an Inspo - it seems to help.

For the original poster, if he hasn't bought a Pursuit yet: If the cell seems to be playing up, try calibrating in a plastic bag of O2 - easier to guarantee 100% O2 for testing.
__________________
www.southwestmafia.com
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 6th January 2008, 14:40   #19 (permalink)
New Member
 
nigelh's Avatar

Current Rebreather/s:
Inspiration Vision
Other CCR

Other Rebreather/s:
Inspiration Classic
Other CCR
 
Join Date: Mar 2005
Location: Brighton, Sussex, UK
Posts: 784
nigelh is a glorious beacon of lightnigelh is a glorious beacon of lightnigelh is a glorious beacon of lightnigelh is a glorious beacon of lightnigelh is a glorious beacon of lightnigelh is a glorious beacon of lightnigelh is a glorious beacon of lightnigelh is a glorious beacon of lightnigelh is a glorious beacon of lightnigelh is a glorious beacon of lightnigelh is a glorious beacon of light
Send a message via MSN to nigelh
Re: about to throw VR3 brick away

I had problems in this area just by misunderstanding the set up procedures for 'CAL GAS'.

Once I stepped through the instructions idiot fashion, read and did every line (desperately hard for an engineer who always knows exactly what to do) I finally got it to set up cleanly.

I admit that with a nice colour text screen it could be a lot more helpful. For things we don't do often we don't need a pretty graphic we need words and numbers. If it said "If you are seriously telling me you are calibrating this on 18/40 trimix why the heck am I getting 50mV out of the cell?" it might even get through to dumb me that maybe I hadn't set it to NX99 like I thought I had. Just "CAL GAS=NX99" would help so much.
__________________
nigelh
(Online)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



RebreatherWorld.Com ©2005 - 2008 Scuba Flair Limited
Rebreather World, Rebreather World and the Rebreather World Logo are Trademarks
All rights reserved, no republishing of content without written permission.
By using this website you have agreed to our Terms & Conditions of Use

Search Engine Optimization by vBSEO 3.1.0