| | #1 (permalink) |
| too legit to quit ![]() Current Rebreather/s: rEvo Other Rebreather/s: rEvo Join Date: Jan 2007 Location: Neuw Yawk
Posts: 263
![]() ![]() ![]() | what cells are you using and why? if you were in say, ny and you needed new cells for say, sunday, for a rEvo, what would you do? can you use a generic AI replacement or does paul do something special to the cells he supplies? |
| (Offline) | |
| | #3 (permalink) |
| rEvo's daddy ![]() Current Rebreather/s: rEvo Other CCR Home Build Other Rebreather/s: rEvo Other CCR Home Build Join Date: May 2005 Location: belgium
Posts: 1,381
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: what cells are you using and why? Its an R22 D just not a standard R22D, the minimum output voltage must be 9 mV in airJust like any other R22 D we now have R22D-rEvo that have that spec, same as the AI-rEvo paul
__________________ www.rEvo-rebreathers.com .... the earth is flat, Elvis is alive, and radial scrubbers give longer dwell time than axials... |
| (Offline) | |
| | #4 (permalink) |
| hell is in the details Current Rebreather/s: RB80 / Clone Home Build Other Rebreather/s: Not Bought Yet RB80 / Clone Home Build Join Date: Sep 2005 Location: FRANCE Carcassonne
Posts: 440
![]() ![]() ![]() ![]() | Re: what cells are you using and why? just not a standard R22D, the minimum output voltage must be 9 mV in air we now have R22D-rEvo that have that spec, same as the AI-rEvo paul Hi Paul, Just curious, did you have both or did you turn "definately" to Teledyne? In any case great thing that you test mv output before sending them ![]() |
| (Offline) | |
| | #5 (permalink) |
| rEvo's daddy ![]() Current Rebreather/s: rEvo Other CCR Home Build Other Rebreather/s: rEvo Other CCR Home Build Join Date: May 2005 Location: belgium
Posts: 1,381
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: what cells are you using and why? Hi Paul, nothing is definately in life: Teledyne's aren't perfect either...Just curious, did you have both or did you turn "definately" to Teledyne? In any case great thing that you test mv output before sending them ![]() we keep testing both, at the moment we supply R22D-rEvo paul
__________________ www.rEvo-rebreathers.com .... the earth is flat, Elvis is alive, and radial scrubbers give longer dwell time than axials... |
| (Offline) | |
| | #6 (permalink) |
| Custom Title Allowed! Current Rebreather/s: Inspiration Classic Inspiration Vision Evolution Sport Kiss Classic Kiss Dolphin Ray Azimuth Home Build Other Rebreather/s: Dolphin Ray Azimuth Home Build Join Date: May 2005 Location: UK
Posts: 621
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: what cells are you using and why? Paul why did you choose 9mv as a minimum? there is some belief in the fact that lower output in air cells actually last longer than higher output in air ones! Dave |
| (Online) | |
| | #8 (permalink) |
| too legit to quit ![]() Current Rebreather/s: rEvo Other Rebreather/s: rEvo Join Date: Jan 2007 Location: Neuw Yawk
Posts: 263
![]() ![]() ![]() | Re: what cells are you using and why? thanks richie, i got a set from DRE as backup, psr 11-39-md type havent checked them on the cell checker yet. the cells i have are doing this which has me concerned mv in air in 02 @.6 bar .7 bar .8 bar 7,0 44.0 49.1 55.0 7.4 47.6 53.6 59.7 11.9 74.9 84.7 93.6 maybe its my skil at graphs or math, but i think the first two are done for. opinions? |
| (Offline) | |
| | #9 (permalink) |
| rEvo's daddy ![]() Current Rebreather/s: rEvo Other CCR Home Build Other Rebreather/s: rEvo Other CCR Home Build Join Date: May 2005 Location: belgium
Posts: 1,381
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: what cells are you using and why? Paul why did you choose 9mv as a minimum? hello Dave, the smaller you make the span of allowed voltage, the less error you can include when calibrating: the unit will reject the cell as beiing to low or to highthere is some belief in the fact that lower output in air cells actually last longer than higher output in air ones! Dave paul
__________________ www.rEvo-rebreathers.com .... the earth is flat, Elvis is alive, and radial scrubbers give longer dwell time than axials... |
| (Offline) | |