Old 7th January 2008, 06:44   #1 (permalink)
New Member
 
weirdo1's Avatar

Current Rebreather/s:
rEvo

Other Rebreather/s:
rEvo
 
Join Date: Aug 2007
Location: The Netherlands
Posts: 45
weirdo1 is an unknown quantity at this point
one cell giving high PO2 readout

Here's a question for the real experienced (rEvo) CCR divers (witch i'm not)
I dive one rEvodream on one cell and the other on two cells

I calibrated my cell's following procedure.

On air all the cells read a po2 of ~0,21. On O2 alle the cells read ~1.0 (On surface) So far OK.

While diving the readout of the cells begin to differ. On the 2 cell rEvodream the difference between the cells in small (~0.01 till 0.03) but if I compare it with the one cell rEvodream the difference is much larger ( ~0.10 higher), with causes a “high” po2 signal on 1C RD, while the 2C RD is perfectly on setpoint (cont. green)
I even had a low and high signal at the same time (on different HUD’s)

After the dive the readout of all the cells are more or less the same (0.01 or less)

Till a coupele of dives ago it wasn't a problem. Both RD and cell readouds were more or less the same.
How can this be? The unit and the cells done about 6 hours of diving. What do I do? Its really bugging me.
__________________
Weirdo has rEvolved

Last edited by weirdo1 : 7th January 2008 at 06:54.
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 7th January 2008, 08:27   #2 (permalink)
rEvo's daddy
 
paulraymaekers's Avatar

Current Rebreather/s:
rEvo
Other CCR
Home Build

Other Rebreather/s:
rEvo
Other CCR
Home Build
 
Join Date: May 2005
Location: belgium
Posts: 1,432
paulraymaekers has much to be proud ofpaulraymaekers has much to be proud ofpaulraymaekers has much to be proud ofpaulraymaekers has much to be proud ofpaulraymaekers has much to be proud ofpaulraymaekers has much to be proud ofpaulraymaekers has much to be proud ofpaulraymaekers has much to be proud ofpaulraymaekers has much to be proud ofpaulraymaekers has much to be proud ofpaulraymaekers has much to be proud of
Re: one cell giving high PO2 readout

Quote: (Originally Posted by weirdo1) View Original Post
Here's a question for the real experienced (rEvo) CCR divers (witch i'm not)
I dive one rEvodream on one cell and the other on two cells

I calibrated my cell's following procedure.

On air all the cells read a po2 of ~0,21. On O2 alle the cells read ~1.0 (On surface) So far OK.

While diving the readout of the cells begin to differ. On the 2 cell rEvodream the difference between the cells in small (~0.01 till 0.03) but if I compare it with the one cell rEvodream the difference is much larger ( ~0.10 higher), with causes a “high” po2 signal on 1C RD, while the 2C RD is perfectly on setpoint (cont. green)
I even had a low and high signal at the same time (on different HUD’s)

After the dive the readout of all the cells are more or less the same (0.01 or less)

Till a coupele of dives ago it wasn't a problem. Both RD and cell readouds were more or less the same.
How can this be? The unit and the cells done about 6 hours of diving. What do I do? Its really bugging me.
Hello Weirdo ??

what is the serie-number of the cells??
best to PM me

regards
paul
__________________
www.rEvo-rebreathers.com

.... the earth is flat, Elvis is alive, and radial scrubbers give longer dwell time than axials...
(Online)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 7th January 2008, 10:25   #3 (permalink)
toni the strange
 
anton610's Avatar

Current Rebreather/s:
Evolution
Other CCR

Other Rebreather/s:
Other CCR
 
Join Date: May 2006
Location: austria
Posts: 170
anton610 is an unknown quantity at this point
Send a message via Skype™ to anton610
Re: one cell giving high PO2 readout

Quote: (Originally Posted by weirdo1) View Original Post
Here's a question for the real experienced (rEvo) CCR divers (witch i'm not)
I dive one rEvodream on one cell and the other on two cells

I calibrated my cell's following procedure.

On air all the cells read a po2 of ~0,21. On O2 alle the cells read ~1.0 (On surface) So far OK.

While diving the readout of the cells begin to differ. On the 2 cell rEvodream the difference between the cells in small (~0.01 till 0.03) but if I compare it with the one cell rEvodream the difference is much larger ( ~0.10 higher), with causes a “high” po2 signal on 1C RD, while the 2C RD is perfectly on setpoint (cont. green)
I even had a low and high signal at the same time (on different HUD’s)

After the dive the readout of all the cells are more or less the same (0.01 or less)

Till a coupele of dives ago it wasn't a problem. Both RD and cell readouds were more or less the same.
How can this be? The unit and the cells done about 6 hours of diving. What do I do? Its really bugging me.
Had the sam problem with my evocells!

New cell... everything allright!
__________________
"Das Übel kommt nicht von der Technik, sondern von denen, die sie mißbrauchen."

Jacques-Yves Cousteau (1910-1997)
(Online)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 7th January 2008, 10:31   #4 (permalink)
flap-flop ..... flap-flop
 
Hanssing's Avatar

Current Rebreather/s:
rEvo

Other Rebreather/s:
rEvo
 
Join Date: Nov 2005
Location: Denmark
Posts: 370
Hanssing is a glorious beacon of lightHanssing is a glorious beacon of lightHanssing is a glorious beacon of lightHanssing is a glorious beacon of lightHanssing is a glorious beacon of lightHanssing is a glorious beacon of lightHanssing is a glorious beacon of lightHanssing is a glorious beacon of lightHanssing is a glorious beacon of lightHanssing is a glorious beacon of lightHanssing is a glorious beacon of light
Re: one cell giving high PO2 readout

Quote: (Originally Posted by weirdo1) View Original Post
While diving the readout of the cells begin to differ. On the 2 cell rEvodream the difference between the cells in small (~0.01 till 0.03) but if I compare it with the one cell rEvodream the difference is much larger ( ~0.10 higher), with causes a “high” po2 signal on 1C RD, while the 2C RD is perfectly on setpoint (cont. green)
I even had a low and high signal at the same time (on different HUD’s)
Hi Weirdo,

Two of my rEvo-cells did exactly the same. Bought some new ones:
The first I recieved was a Teldyne. This reacts FAST compared to the AII.
The next two ones were AII, but form the infamous batch with errors.

I REALLY don't like cells right now......

Nicolai
__________________
Woohooo - I can change my rEvo!
Its going to be bitchin' tricked out piece of gear
(Online)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 7th January 2008, 16:59   #5 (permalink)
Custom Title Allowed!
 
J. V.'s Avatar

Current Rebreather/s:
rEvo

Other Rebreather/s:
Not Bought Yet
rEvo
 
Join Date: Mar 2006
Location: Lot & Savoie
Posts: 233
J. V. will become famous soon enoughJ. V. will become famous soon enoughJ. V. will become famous soon enough
Re: one cell giving high PO2 readout

It's probably a cell failure.
Some month ago I've tested few cells on my rEvodreams, after calibration all given 1.00 at surface. A six meter on pure O2 one come to give too much, around 1.70. At 40 meters the same give 4.00 . Back on surface after one hour dive it give around .21 in air...
__________________
--------------------
Jacques
NPSFQQA-EDS IT # 007
(remué non agité)
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 10th January 2008, 07:00   #6 (permalink)
New Member
 
weirdo1's Avatar

Current Rebreather/s:
rEvo

Other Rebreather/s:
rEvo
 
Join Date: Aug 2007
Location: The Netherlands
Posts: 45
weirdo1 is an unknown quantity at this point
Re: one cell giving high PO2 readout

Quote: (Originally Posted by paulraymaekers) View Original Post
Hello Weirdo ??

what is the serie-number of the cells??
best to PM me

regards
paul
u have a PM
__________________
Weirdo has rEvolved
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 21st January 2008, 16:50   #7 (permalink)
New Member
 
weirdo1's Avatar

Current Rebreather/s:
rEvo

Other Rebreather/s:
rEvo
 
Join Date: Aug 2007
Location: The Netherlands
Posts: 45
weirdo1 is an unknown quantity at this point
Re: one cell giving high PO2 readout

Paul replaced ALL my cells!(unused spare cell as well)

My cells weren't from the recall batch, but close enough to replace them.

Tnx Paul, great service!
__________________
Weirdo has rEvolved
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



RebreatherWorld.Com ©2005 - 2008 Scuba Flair Limited
Rebreather World, Rebreather World and the Rebreather World Logo are Trademarks
All rights reserved, no republishing of content without written permission.
By using this website you have agreed to our Terms & Conditions of Use

Search Engine Optimization by vBSEO 3.1.0