| | #1 (permalink) |
| New Member Current Rebreather/s: rEvo Other Rebreather/s: rEvo Join Date: Apr 2007 Location: Melbourne
Posts: 3
![]() | rEvo rebreathers cooperates with Shearwater Research inc Paul, Good to see this announcement on Rebreather Word Forums. Can you give us any more informations about it? In particular, can it run cells in parallel? (as Dave suggested) Rob. |
| (Offline) | |
| | #2 (permalink) |
| rEvo's daddy ![]() Current Rebreather/s: rEvo Other CCR Home Build Other Rebreather/s: rEvo Other CCR Home Build Join Date: May 2005 Location: belgium
Posts: 1,498
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: rEvo rebreathers cooperates with Shearwater Research inc Paul, yes it can!, can it run cells in parallel? (as Dave suggested) Rob. the normal setup I advise: 3 cells on the pursuit, and of those 3 cells, 2 of them are paralled on the first rEvodream: this way the PPO2 the pursuit delivers you is shown on the rEvodream gauge/HUD 4th cell on the second rEvodream only : totally independant verifying system, also shown on the second HUD OK, now everybody thinks: you can show the non-paralled 3th cell of the pursuit also on that second rEvodream: NO: you loose complete redundancy regards paul
__________________ www.rEvo-rebreathers.com .... the earth is flat, Elvis is alive, and radial scrubbers give longer dwell time than axials... |
| (Offline) | |