| | #1 (permalink) |
| The Evolution of Diving Current Rebreather/s: Evolution Other SCR Other Rebreather/s: Not Bought Yet Other SCR Join Date: May 2005 Location: Victoria BC Canada
Posts: 349
| HS Explorer Sensor error I have the HSE model O. I completed a dive yesterday (135/30) on my Rebreather and all was well. Today I changed the O2 sensors in the RB and went to calibrate the HSE and for some reason it would not read the sensor at all. I checked the voltage at the sensor and at the end of the cable and the reading was the same. When I hooked the sensor to the computer the reading on the computer was 59mv in stead of 50mv and the PPO2 reading was 0.8. I went to the manual and rechecked to make sure I had not set the unit up wrong but everything was set correct. Finally I hooked the computer to my PC and downloaded the mix table and uploaded the dive profiles. After this was done the unit worked great! The only thing I can think of is at the end of the dive yesterday I switched to OC to practice some BO drills and then surfaced and left the computer in the OC mode with the sensor on. If anyone has any info as to what might have caused this I would appreciate it. Thanks Rob |
| (Offline) | |
| | #2 (permalink) |
| Moderator ![]() Current Rebreather/s: Inspiration Classic Sport Kiss Optima rEvo Other CCR Other Rebreather/s: Inspiration Vision Evolution Megalodon Classic Kiss rEvo Other CCR Join Date: Mar 2005 Location: "Da" Bronx
Posts: 3,113
| Re: HS Explorer Sensor error Quote: (Originally Posted by diverrob) I have the HSE model O. I completed a dive yesterday (135/30) on my Rebreather and all was well. Today I changed the O2 sensors in the RB and went to calibrate the HSE and for some reason it would not read the sensor at all. I checked the voltage at the sensor and at the end of the cable and the reading was the same. When I hooked the sensor to the computer the reading on the computer was 59mv in stead of 50mv and the PPO2 reading was 0.8. I went to the manual and rechecked to make sure I had not set the unit up wrong but everything was set correct. Finally I hooked the computer to my PC and downloaded the mix table and uploaded the dive profiles. After this was done the unit worked great! The only thing I can think of is at the end of the dive yesterday I switched to OC to practice some BO drills and then surfaced and left the computer in the OC mode with the sensor on. If anyone has any info as to what might have caused this I would appreciate it. Thanks Before you calibrate, you must be set to mix 0, 1 or 2.. and po2 mode on..Rob if you are on mix 3, or 4 or any of the oc gases it will not calibrate..
__________________ Joe Radomski CCR Trimix Instructor Trainer ANDI Instructor Trainer Director #10 All posts are personal opinions and DO NOT reflect any affiliated agency unless specifically stated. |
| (Offline) | |
| | #3 (permalink) |
| The Evolution of Diving Current Rebreather/s: Evolution Other SCR Other Rebreather/s: Not Bought Yet Other SCR Join Date: May 2005 Location: Victoria BC Canada
Posts: 349
| Re: HS Explorer Sensor error Yes I thought that may be the problem but I did switch it back to mix 0 before starting this whole evolution. Thanks though |
| (Offline) | |