![]() | Shearwater one-cell wireing to fisher?? The questionmark is aboute what is wrong whith this picture?? I have one cell connected (is it wired wrong??) The tre-cell indicators blinking? SW- Cell.JPG Have tried to calibrate and i thaught that it would adjuste to one-cell reading on auto if onley one cell was connected? Is I wrong or are the wireing in the fischer contakt wrong? Thanks. Johan
__________________ I'm done playing, geti'ng me a Pelagian..Payed and ordered ![]() Better to rule in hell than to serve in heven !!http://hem.bredband.net/gixxer750 http://www.dykarna.nu/?userId=3603 |
| (Offline) | |
| | #2 (permalink) |
| New Member Current Rebreather/s: Other CCR Dolphin Azimuth Other SCR Home Build Other Rebreather/s: Not Bought Yet Other CCR Dolphin Azimuth Other SCR Home Build Join Date: Jul 2006 Location: Caribbean, Germany
Posts: 61
![]() ![]() ![]() ![]() ![]() | Re: Shearwater one-cell wireing to fisher?? The questionmark is aboute what is wrong whith this picture?? Hi Johan,I have one cell connected (is it wired wrong??) The tre-cell indicators blinking? Attachment 9274 Have tried to calibrate and i thaught that it would adjuste to one-cell reading on auto if onley one cell was connected? Is I wrong or are the wireing in the fischer contakt wrong? Thanks. Johan you must conect it to the "middle" cell. I think you have a black cabel So use GREEN for minus and GREY for positive if you connect only one cell. Pining Pin 1 -> grün/green/verde (Minus all sensors) Pin 2 -> gelb/yellow/jaune Pin 3 -> grau/grey/gris Pin 4 -> rosa/pink Any more questions? Hope this helps. Cheers Martin
__________________ www.tecme.de |
| (Offline) | |
| | #3 (permalink) |
| New Member Current Rebreather/s: Pelagian Other CCR Azimuth Other Rebreather/s: Not Bought Yet Pelagian Other CCR Azimuth Join Date: Dec 2005 Location: Sweden / Nynashamn
Posts: 44
![]() | Re: Shearwater one-cell wireing to fisher?? Hi Johan, Thank's Martin you must conect it to the "middle" cell. I think you have a black cabel So use GREEN for minus and GREY for positive if you connect only one cell. Pining Pin 1 -> grün/green/verde (Minus all sensors) Pin 2 -> gelb/yellow/jaune Pin 3 -> grau/grey/gris Pin 4 -> rosa/pink Any more questions? Hope this helps. Cheers Martin I will try this and get back to you all.. Thaught it was something like this.. :-) Happy diver.
__________________ I'm done playing, geti'ng me a Pelagian..Payed and ordered ![]() Better to rule in hell than to serve in heven !!http://hem.bredband.net/gixxer750 http://www.dykarna.nu/?userId=3603 |
| (Offline) | |
| | #4 (permalink) |
| Home of the TR300 ![]() Current Rebreather/s: | Re: Shearwater one-cell wireing to fisher?? Thank's Martin In my mind I remember that the shearwater does not calibrate when not all 3 cells are connectect. If you use only one cell, best is to connect all 3 inlets (pins 2+3+4) together at on cell, so all three readings shows the same value. then its easy to calibrate, or wait for the SCR option (but not knowing if it works with one cell I will try this and get back to you all.. Thaught it was something like this.. :-) Happy diver. )regards Holger
__________________ If it makes bubbles it means its brocken Visit: www.tr300.com, Missions: www.rebreatherteam.de |
| (Offline) | |
| | #5 (permalink) |
| rEvo's daddy ![]() Current Rebreather/s: rEvo Other CCR Home Build Other Rebreather/s: rEvo Other CCR Home Build Join Date: May 2005 Location: belgium
Posts: 1,423
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: Shearwater one-cell wireing to fisher?? In my mind I remember that the shearwater does not calibrate when not all 3 cells are connectect. If you use only one cell, best is to connect all 3 inlets (pins 2+3+4) together at on cell, so all three readings shows the same value. then its easy to calibrate, or wait for the SCR option (but not knowing if it works with one cell hello Holger, the shearwater pursuit calibrates correct on one cell if you connect it to input nr 2 (the middle reading) )regards Holger if done so, itwill not show the 0.00 on the left and right regards paul
__________________ www.rEvo-rebreathers.com .... the earth is flat, Elvis is alive, and radial scrubbers give longer dwell time than axials... |
| (Offline) | |