![]() | constant ip reg?? hey guys, can the dive rite rg 1208 first stage be converted to a conspant ip reg by just adding the blanking plug like in the ds4's ?? the one i have now already has the cold water kit. thanks for the help Last edited by sidis8 : 28th October 2007 at 19:17. |
| (Online) | |
| | #3 (permalink) |
| Dave Tomblin ![]() ![]() Current Rebreather/s: Megalodon Other CCR Other Rebreather/s: Not Bought Yet Inspiration Classic Sport Kiss Other CCR Join Date: Feb 2005 Location: Vancouver Island BC Canada
Posts: 1,444
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: constant ip reg?? hey guys, can the dive rite rg 1208 first stage be converted to a conspant ip reg by just adding the blanking plug like in the ds4's ?? the one i have now already has the cold water kit. thanks for the help Does it have a mushroom shaped plastic piece under the environmental seal? I think removing that will have the same effect.
__________________ Cheers, Dave.... Man is the only animal burdened with the knowledge he will eventually die |
| (Offline) | |
| | #4 (permalink) |
| New Member Current Rebreather/s: Megalodon Other Rebreather/s: Join Date: Sep 2006 Location: Edmonton
Posts: 38
![]() | Re: constant ip reg?? Does it have a mushroom shaped plastic piece under the environmental seal? I think removing that will have the same effect. Dave,Harcus's just had 1/8" of the tip of the plastic cut off on his 1st stage plastic "T". Shorting it enough so it does not touch the diaphram. Sidis8 No need to buy a blanking plug. If you have a look at the plastic "T" the end tapers off like a step. Cut it off with a dremel saw or small saw were it steps down. Last edited by hillbilly : 29th October 2007 at 14:11. |
| (Offline) | |
| | #5 (permalink) |
| Dave Tomblin ![]() ![]() Current Rebreather/s: Megalodon Other CCR Other Rebreather/s: Not Bought Yet Inspiration Classic Sport Kiss Other CCR Join Date: Feb 2005 Location: Vancouver Island BC Canada
Posts: 1,444
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: constant ip reg?? Dave, That sounds painfulHarcus's just had 1/8" of the tip of the plastic cut off on his 1st stage plastic "T". Shorting it enough so it does not touch the diaphram. . ![]()
__________________ Cheers, Dave.... Man is the only animal burdened with the knowledge he will eventually die |
| (Offline) | |
| | #6 (permalink) |
| John Harcus Current Rebreather/s: Megalodon Other Rebreather/s: Join Date: Jun 2006 Location: Calgary, Alberta
Posts: 258
![]() ![]() ![]() ![]() ![]() ![]() | Re: constant ip reg?? Dave, I hadn't noticed myself, it's probably a good thing though, as an 1/8" off the tip doesn't really affect things being so "Big" and all.Harcus's just had 1/8" of the tip of the plastic cut off on his 1st stage plastic "T". Shorting it enough so it does not touch the diaphram. Sidis8 No need to buy a blanking plug. If you have a look at the plastic "T" the end tapers off like a step. Cut it off with a dremel saw or small saw were it steps down. That sounds painful Nah...it IS important to make sure it doesn't touch the diaphragm, what would happen if that diaphragm were to be punctured? One could become "partially IP'd"![]()
__________________ Regards; "Some people shouldn't dive...others shouldn't even get wet". Last edited by jdicediver : 29th October 2007 at 23:41. |
| (Offline) | |