| | #1 (permalink) |
| Wael AL-Jareh ![]() | Flow Meters Which type/model do you use on your mCCR/hCCR ? Regards. Wael
__________________ Euro Diving Zone (HP Kevlar Fiber Hoses, LP Thermoplastic Hoses, Oxygen Boosters, Carbon Fiber Cylinders, SS Fittings) TDI Inspiration/Evolution Instructor SITEC Oxygen Boosters |
| (Online) | |
| | #2 (permalink) |
| Steve Rich rEvo II Classic/Sport KISS Join Date: Jun 2007 Location: Upstate NY
Posts: 489
| Re: Flow Meters With the Dolphin, I used the Dwyer MiniMaster, the same model that came with the Dolphin could be bought directly from dwyer for a fraction of the cost. For mCCR, I use the "Dave ****** inverted graduated cylinder in a bucket of water" method, the output hose from the orifice goes into the water, and bleeds gas over time into a flooded and inverted graduated cylinder. The amount of water displaced, factored with the time of the sample (example: 125ml in 10 seconds= 0.75 liters/min), gives an actual reading of gas volume per minute, without having to worry about whether the calibrations of the flow meter is in air or O2. Seems to have worked well for me so far. Which type/model do you use on your mCCR/hCCR ? Regards. Wael |
| (Offline) | |
| | #3 (permalink) |
| Acme Serpentine Lubricant Join Date: Mar 2005 Location: North...
Posts: 2,319
| Re: Flow Meters I used a Dwyer, can't remember the model number but Gordon lists it in the KISS manual. IIRC it's a 0-2l/min but might be wrong as it's from memory. You will need to correct for oxygen as they are calibrated in air. Once you have the flow set then you can check the flow in the field by just timing how long it takes the oxygen lines to depressurise once the oxygen is switched off. It's rough but it's an easy check to do predive. |
| (Offline) | |
| | #4 (permalink) |
| Explorers Exodus rEvo-II Join Date: Nov 2005 Location: Denmark
Posts: 883
| Re: Flow Meters ahh for a mCCR/hCCR --> none. Get the pressure to match your metabolism, and write down droptime from say 100 to 50 bars. Use this as a ballpark figure during preparation at home. I still see this as a "critical" function on a mCCR, and therefor I test it during preparation of the rig at home. However, so what if it doesnt? We check PPO often enough right...... Nicolai |
| (Offline) | |
| | #5 (permalink) |
| RBW Member ![]() rEvo 3 MICRO FT rEvo 3 Standard HCCR, MEG 2.01 Join Date: Aug 2008 Location: US
Posts: 804
| Re: Flow Meters +1 for Dwyer. Mine is an 02 flow meter, so no calculation from air needed. below is pic of it.. Albeit not the best photo.. hope it helps.. John |
| (Offline) | |
| | #6 (permalink) |
| RBW Member Inspiration, Micro rEvo Join Date: Jan 2006 Location: NC
Posts: 187
| Re: Flow Meters I use the Dwyer Model # VFB -60-SS, which you can order directly. Lately thought it's simpler to use an empty Jim Bean 1/5. 750ml,, so 1 minute to fill equals .75lpm flow.......... |
| (Offline) | |
| | #7 (permalink) |
| RBW Member Dolphin mCCR Join Date: Jan 2006 Location: Belgium
Posts: 224
| Re: Flow Meters I use the Dwyer 1,2 l/m purchased through Tecme. (air model) I use it every time doing predive checks. If anything is wrong, its easy noticed : Flow too high : ball above .. happened to me once due to OČ IP creeped up Flow too low : filter clogged, re-adjustment of y Swagelock needle valve. cheers Ivan |
| (Offline) | |
| | #8 (permalink) |
| Casual Sport Kiss Pilot | Re: Flow Meters I use the Dwyer 1,2 l/m purchased through Tecme. (air model) I use it every time doing predive checks. If anything is wrong, its easy noticed : Flow too high : ball above .. happened to me once due to OČ IP creeped up Flow too low : filter clogged, re-adjustment of y Swagelock needle valve. cheers Ivan Second that, I also use a flow meter which i purchased from Martin (tecme) |
| (Offline) | |
![]() |