| New Member Current Rebreather/s: | HELP with VR£ I am trying to calibrate my VR£ to use an external O2 sensor. All I can get is a reading of 326.4, what am I doing wrong, I am calibrating in ambient air so the reading should be 21. can someone please help? ![]() |
| (Offline) | |
| | #2 (permalink) |
| RBW Member Current Rebreather/s: Classic Kiss Other Rebreather/s: Inspiration Classic Join Date: Jan 2005 Location: Kent
Posts: 2,853
| Re: HELP with VR£ I am trying to calibrate my VR£ to use an external O2 sensor. All I can get is a reading of 326.4, what am I doing wrong, I am calibrating in ambient air so the reading should be 21. can someone please help? ![]() More than likley you have not set the calibration gas up corectly. You have to go to 21% on the gas list switch to 21% and save it as the calibration gas before you calibrate. Mind you i only ever calibrated it in 100% ?? but this should work. ATB Mark Chase
__________________ See my "Doing It Chasey" video where I'm locked into a padded room, naked, with two ball bearings and within an Hour, I manage to lose one and break the other!!! Kevin Juergensen 16/11/08 [/quote] Last edited by Mark Chase : 19th April 2007 at 19:41. |
| (Online) | |
| | #3 (permalink) |
| New Member Current Rebreather/s: | Re: HELP with VR£ More than likley you have not set the calibration gas up corectly. You have to go to 21% on the gas list switch to 21% and save it as the calibration gas before you calibrate. Thanks Mark, set cal gas to air and now it works fine, all set-up ready for Stoney tomorrow.Mind you i only ever calibrated it in 100% ?? but this should work. ATB Mark Chase ![]() |
| (Offline) | |
| | #4 (permalink) |
| Custom Title Allowed! Current Rebreather/s: | Re: HELP with VR£ Thanks Mark, set cal gas to air and now it works fine, all set-up ready for Stoney tomorrow. Hi Diveuk,![]() As Mark did mention it is better to Calibrate using 100% Oxygen. You do have to turn on the .99 gas and select it as the Cal gas and then turn it off again after calibrating but at least you will know your sensor can indeed read higher Oxygen readings than 21% Regards |
| (Offline) | |
| | #5 (permalink) |
| New Member Current Rebreather/s: | Re: HELP with VR£ Hi Diveuk, Thanks Barry, will calibrate with 100% O2 tomorrow or is that today As Mark did mention it is better to Calibrate using 100% Oxygen. You do have to turn on the .99 gas and select it as the Cal gas and then turn it off again after calibrating but at least you will know your sensor can indeed read higher Oxygen readings than 21% Regards ![]() |