CCR Gas Consumption

Hello,

For comparative purposes, I need a to figure out gas consumption on CCR, at depths of 10m - 100m.

Any help would be greatly appreciated!

Regards,

Lawrence
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 25th July 2010, 16:02   #2 (permalink)
Ryan Battles
 
battles2a5's Avatar

 
rEvo II mini
Join Date: Jul 2007
Location: Charlotte, NC
Posts: 250
battles2a5 has a spectacular aura about battles2a5 has a spectacular aura about battles2a5 has a spectacular aura about battles2a5 has a spectacular aura about battles2a5 has a spectacular aura about
Re: CCR Gas Consumption

Gas consumption on a CCR is nowhere near as cut and dry as on OC. For one thing, you have 2 gases to consider; Oxygen and Diluent.

Oxygen consumption during descent and the bottom portion of the dive is largely based on the metabolism of the diver. On ascent, the o2 consumption will rise, but the degree of increase is based largely on the way the diver manages the loop (e.g. the closer you stay to min loop, the less oxygen you will need to maintain a higher PO2 during ascent and deco).

On a square profile, diluent consumption is heavily front loaded. The majority of the volume used will happen during descent as the loop is compressed and the unit makes up the volume w/ dil. From that point forward, small amounts may be added for corrections, adjustments, and the small amount that is absorbed by the body. Again, the amount that is used is largely determined by the technique (e.g. minimum loop w/ good discipline around nose breathing requires much less gas than a full loop and poor discipline).

So just like everything else in rebreathers, it just isn't that simple. Good instruction and good dive logging will help you determine your own consumption rates for planning. There are really no hard and fast guidelines out there.
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 25th July 2010, 16:38   #3 (permalink)
LJM
RBW Member
 
LJM's Avatar

 
Join Date: Mar 2008
Location: UK
Posts: 8
LJM is an unknown quantity at this point
Re: CCR Gas Consumption

Thanks Ryan,

That confirms what I has 'guessed', thinking it through logically (I'm not CCR trained.

Is it possible to typical value, or order of magnitude? It's for a comparison as part of an academic paper, so is only indicative.

Thanks,

Lawrence
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 25th July 2010, 18:42   #4 (permalink)
Ryan Battles
 
battles2a5's Avatar

 
rEvo II mini
Join Date: Jul 2007
Location: Charlotte, NC
Posts: 250
battles2a5 has a spectacular aura about battles2a5 has a spectacular aura about battles2a5 has a spectacular aura about battles2a5 has a spectacular aura about battles2a5 has a spectacular aura about
Re: CCR Gas Consumption

Well, Boyle's still applies. So if you measure the total system volume (your respiratory system + the total loop volume) you'll know the volume that will need to be replaced as you descend. So let's say for arguments sake that you have a 12L system; If you assume you start the dive with a full loop, you would need roughtly 12L of DIL for every 10M of depth you descend. You need to account for adjustments/ corrections, etc. as you go. So what you'll find is that a 2L or 3L dil tank will cover just about any dive you want to do. The reserves are what is important for bail-out (if you do it onboard), SCR, and flushing.

1L-1.5L/min for O2 is a reasonable planning rate.
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 26th July 2010, 14:29   #5 (permalink)
Rebreather addicted
 
wizebt's Avatar

 
ISC Megalodon
Inspiration, Sentinel, Dolphin
Join Date: Nov 2007
Location: La Gaude, France
Posts: 203
wizebt has a spectacular aura about wizebt has a spectacular aura about wizebt has a spectacular aura about wizebt has a spectacular aura about wizebt has a spectacular aura about wizebt has a spectacular aura about
Send a message via MSN to wizebt
Re: CCR Gas Consumption

As an indication

On the inspiration/vision, a typical one hour dive with max depth 45m and min loop discipline but using diluent to inflate wing I usually use
30 to 50bar oxygen on a 3 liter cylinder
60 bar diluent

~5 to 10 bar oxygen is used for cell calibration, pre-breathing and surface swimming and waiting. Included in the values above.

Most of the oxygen is used in the ascend phase to enrich the loop and decrease the deco stop. I tend to run pure oxygen @ 6m (in reality it is 0.85).
(Online)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 26th July 2010, 16:47   #6 (permalink)
So many CCR So little etc
 
Mark Chase's Avatar

 
JJ Hybrid
Inspo, Hammer Head, KISS rEvo
Join Date: Jan 2005
Location: Kent
Posts: 4,962
Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute
Re: CCR Gas Consumption

Depth dosent apear relevent except for very shalow dives


A 3 hour dive to 70m i use 50-60 bar 02 and 50-60bar Diluient out of a 3ltr

Same for a 30m dive

But on a 15m dive in mexico with a lot of up and down stuff Id use 60 bar 02 and 100bar dill.


Basicly I wont jump in and do a dive with less than 150 bar. 02 or dill


ATB

Mark
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 27th July 2010, 08:13   #7 (permalink)
Rebreather addicted
 
wizebt's Avatar

 
ISC Megalodon
Inspiration, Sentinel, Dolphin
Join Date: Nov 2007
Location: La Gaude, France
Posts: 203
wizebt has a spectacular aura about wizebt has a spectacular aura about wizebt has a spectacular aura about wizebt has a spectacular aura about wizebt has a spectacular aura about wizebt has a spectacular aura about
Send a message via MSN to wizebt
Re: CCR Gas Consumption

Quote: (Originally Posted by Mark Chase) View Original Post
Depth dosent apear relevent except for very shalow dives


A 3 hour dive to 70m i use 50-60 bar 02 and 50-60bar Diluient out of a 3ltr

Same for a 30m dive

But on a 15m dive in mexico with a lot of up and down stuff Id use 60 bar 02 and 100bar dill.


Basicly I wont jump in and do a dive with less than 150 bar. 02 or dill


ATB

Mark
Mark,

Don't understand the rational behind your conclusion: why would you need 150b+ of O2 if you routinely use max 60bars?

I routinely jump with 100bar ending with 50bat that gives a good safety margin of another hour.

Did I missed something?
Emmanuel
(Online)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 27th July 2010, 08:49   #8 (permalink)
So many CCR So little etc
 
Mark Chase's Avatar

 
JJ Hybrid
Inspo, Hammer Head, KISS rEvo
Join Date: Jan 2005
Location: Kent
Posts: 4,962
Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute Mark Chase has a reputation beyond repute
Re: CCR Gas Consumption

Quote: (Originally Posted by wizebt) View Original Post
Mark,

Don't understand the rational behind your conclusion: why would you need 150b+ of O2 if you routinely use max 60bars?

I routinely jump with 100bar ending with 50bat that gives a good safety margin of another hour.

Did I missed something?
Emmanuel

Every one has an idea of their safety reserve and for me 90bar in a 3ltr is a what I settled on.

I am committing to 3hours because on avg 2hours 15mins of the three, will be deco. 150 bar leaves 90 bar in a 3 to cover accidental loss of 02 or massive extensions on deco due to a problem forcing a long stay on the bottom etc.


I have loads of spare diluent via my bailouts but all my spare 02 is in my 3ltr unless I use the 50% to try and deco out on via the unit. IF the drop tank turns up ill have 80% to use but i never rely totally on the drop tank.

That said 150 is just my idea. Oter people have diferent ideas, and thats fine.

ATB

Mark
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

BB code is On
Smilies are On
[IMG] code is On
HTML code is On
Trackbacks are On
Pingbacks are On
Refbacks are On




All times are GMT. The time now is 19:56.


RebreatherWorld.Com 2005 - 2013
Rebreather World, RBW and the Rebreather World Logo are Trademarks
All rights reserved, no republishing of content without written permission.
By using this website you have agreed to our Terms & Conditions of Use

free counters

Search Engine Optimization by vBSEO 3.1.0

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675 676 677 678 679 680 681 682 683 684 685 686 687 688 689 690 691 692 693 694 695 696 697 698 699 700 701 702 703 704 705 706 707 708 709 710 711 712 713 714 715 716 717 718 719 720 721 722 723 724 725 726 727 728 729 730 731 732 733 734 735 736 737 738 739 740 741 742 743 744 745 746 747 748 749 750 751 752 753 754 755 756 757 758 759 760 761 762 763 764 765 766 767 768 769 770 771 772 773 774 775 776 777 778 779 780 781 782 783 784 785 786 787 788 789 790 791 792 793 794 795 796 797 798