| | #21 (permalink) |
| New Member Current Rebreather/s: Inspiration Classic Other Rebreather/s: Join Date: Jan 2007 Location: Scotland
Posts: 81
![]() ![]() ![]() ![]() | Re: Handsets disagree on MV values What comes new with an O2ptima ? What comes with a Hammer Head ? AI recomends two types one with a higher out-put. PSR-11-39-MD PSR-11-39-MD [] - $70.00 : CCRsense, Oxygen Sensors for Closed Circuit Rebreathers PSR-11-39-MHD PSR-11-39-MHD [] - $70.00 : CCRsense, Oxygen Sensors for Closed Circuit Rebreathers What is recomended ? |
| (Offline) | |
| | #22 (permalink) |
| New Member Current Rebreather/s: Optima Other Rebreather/s: Optima Join Date: Jan 2007 Location: Ljungsbro_Sweden
Posts: 18
![]() ![]() ![]() | Re: Handsets disagree on MV values What comes new with an O2ptima ? What comes with a Hammer Head ? Optimas are delivered with AI cells .....AI recomends two types one with a higher out-put. PSR-11-39-MD PSR-11-39-MD [] - $70.00 : CCRsense, Oxygen Sensors for Closed Circuit Rebreathers PSR-11-39-MHD PSR-11-39-MHD [] - $70.00 : CCRsense, Oxygen Sensors for Closed Circuit Rebreathers What is recomended ? Technical SCUBA Diving Equipment for Advanced, Wreck and Cave Diving: Dive Rite, Inc. - Catalog - Oxygen Sensor Cell Worried again ....... |
| (Offline) | |
| | #23 (permalink) |
| Moderator ![]() ![]() Current Rebreather/s: Inspiration Classic Sport Kiss Optima rEvo Other CCR Home Build Other Rebreather/s: Inspiration Vision Evolution Megalodon Classic Kiss rEvo Other CCR Home Build Join Date: Mar 2005 Location: "Da" Bronx
Posts: 2,997
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: Handsets disagree on MV values What comes new with an O2ptima ? What comes with a Hammer Head ? AI recomends two types one with a higher out-put. PSR-11-39-MD PSR-11-39-MD [] - $70.00 : CCRsense, Oxygen Sensors for Closed Circuit Rebreathers PSR-11-39-MHD PSR-11-39-MHD [] - $70.00 : CCRsense, Oxygen Sensors for Closed Circuit Rebreathers What is recomended ? I have use r22ds and both AI cells.. the only difference in the MHD (for AI) is that it has a higher guaranteed low working voltage (9mv vs 8.5) so in theory the MHD is a better choice but either will work as long as you get 40mv in 100% oxygen. Teledyne cells are only guaranteed to be 7mv which would not work on a HH.. Most (but not all) teledyne's I have seen over the years have been at least 8.5mv
__________________ Joe Radomski CCR Trimix Instructor Trainer ANDI Instructor Trainer Director #10 All posts are personal opinions and DO NOT reflect any affiliated agency unless specifically stated. |
| (Online) | |