How We Wired All 3 Cells Into The Sheawater

Last year Andy Taylor with a bit of help from my good self designed the 4th cell/auxiliary adapter for the Meg allowing a cable to be fiited through the head without cutting or modifying the unit (see previous posts).
It worked extremely well with a VR3 but having a Shearwater only wired to 1 cell is a bit of a waste so we embarked on wiring it to all 3 cells.
Getting the cable through the head is easy with Andy,s little invention, its whats the best and simplest way to wire all 3 cells in that’s difficult especially for someone who fuses the house every time he fits a plug to something so I got in touch with John Routley at Narked@90.
I explained to John that I wanted to wire all 3 cells to my Shearwater but wanted to unwire it if neccesery in a few minutes on a rolling boat just incase anything went wrong on a trip. I also wanted it to be neat and tidy
(I hate wires everywhere).
John spent many hours making bits for me but in the end we decided the simplest and cheapest way was to push the pins strait into the back of the Megs Molex connectors ( see Shearwaters site, FAQ No7)

Below you will see the pictures I have taken.

In Order.......
1/ This is the Ficsher Cable from Narked@90 with the auxiliary adapter fitted.

2/ This is the exhalation hose fitting removed. The auxiliary fitting is then put in its place and the exhalation hose fitting is then fitted back on top adding about 3cm to the hose.

3/ This it the cable routed along the Meg cables so keeping it nice and neat and also strengthening the Megs cableing.

4/ Here you can see each of the 2 cables running into the top of each cell.

5/ Again you can see each of the 2 cables running into the top of each cell.

6/ The Meg and Shearwater working in perfect harmony haha. In water they work perfectly.

I would like to say a massive thanks to Andy Taylor for his help and to John Routley at Narked@90 for his patience and his help and also to Bruce at Shearwater for a superb product.
Attached Images
File Type: jpg DSC04873.JPG (94.1 KB, 348 views)
File Type: jpg DSC04874.JPG (73.6 KB, 346 views)
File Type: jpg DSC04876.JPG (99.1 KB, 343 views)
File Type: jpg DSC04880.JPG (97.0 KB, 343 views)
File Type: jpg DSC04882.JPG (67.6 KB, 344 views)
File Type: jpg DSC04883.JPG (67.3 KB, 346 views)
__________________
Practice, Practice, Practice And Become A Master Of Technique .............

Last edited by jkeep : 22nd April 2008 at 20:25. Reason: formating
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 22nd April 2008, 20:54   #2 (permalink)
What is this..terrafirma?
 
mempilot's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
Megalodon
 
Join Date: Aug 2006
Location: Ft. Lauderdale
Posts: 830
mempilot is a name known to allmempilot is a name known to allmempilot is a name known to allmempilot is a name known to allmempilot is a name known to allmempilot is a name known to allmempilot is a name known to allmempilot is a name known to allmempilot is a name known to allmempilot is a name known to allmempilot is a name known to all
Re: How We Wired All 3 Cells Into The Sheawater

Very nice! Any field reports yet?
__________________
MEM "Da Pilot"

Black holes are where God divided by zero.

"If at first you don't succeed, don't dive silent."

"Would you mind not shooting at the thermo-nuclear weapons." ~ Vic Deakins

"Donkey's kill more people annually than plane crashes."
(Online)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 22nd April 2008, 21:00   #3 (permalink)
New Member
 
jkeep's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
Inspiration Classic
Inspiration Vision
Megalodon
 
Join Date: Feb 2007
Location: UK
Posts: 48
jkeep is on a distinguished roadjkeep is on a distinguished road
Re: How We Wired All 3 Cells Into The Sheawater

Just that it worked like a dream

I used to have a vision and its pretty much like runnin a vision except
you dont get a battery warning on every dive haha

I,m happy using my Shearwater as the primary and the Meg primary
as my secondary + my HUD

ALWAYS KNOW YOU PPO2 (times 4 now haha)

Jeff
__________________
Practice, Practice, Practice And Become A Master Of Technique .............
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 23rd April 2008, 01:04   #4 (permalink)
All The Gear, No Idea
 
windymiller's Avatar

Current Rebreather/s:
Inspiration Classic
Evolution
Megalodon

Other Rebreather/s:
 
Join Date: Oct 2005
Location: england
Posts: 203
windymiller is on a distinguished roadwindymiller is on a distinguished road
Re: How We Wired All 3 Cells Into The Sheawater

what was the cost?

Im thinking about doing this to my COPIS
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 23rd April 2008, 04:57   #5 (permalink)
Custom Title Allowed!
 
Nailer99's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
 
Join Date: Jan 2007
Location: Seattle, WA, USA
Posts: 131
Nailer99 has a spectacular aura aboutNailer99 has a spectacular aura aboutNailer99 has a spectacular aura aboutNailer99 has a spectacular aura aboutNailer99 has a spectacular aura about
Re: How We Wired All 3 Cells Into The Sheawater

Quote: (Originally Posted by windymiller) View Original Post
what was the cost?

Im thinking about doing this to my COPIS

My COPIS has had the Shearwater wired to all 3 cells since day 1, and I couldn't be happier with it- You'll love it.
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 23rd April 2008, 08:20   #6 (permalink)
Dive porn pimp


 
divetheworld's Avatar

Current Rebreather/s:
Inspiration Classic
Other CCR

Other Rebreather/s:
Not Bought Yet
Inspiration Classic
Inspiration Vision
Classic Kiss
Other CCR
 
Join Date: Mar 2005
Location: Leeds, England
Posts: 1,485
divetheworld has a reputation beyond reputedivetheworld has a reputation beyond reputedivetheworld has a reputation beyond reputedivetheworld has a reputation beyond reputedivetheworld has a reputation beyond reputedivetheworld has a reputation beyond reputedivetheworld has a reputation beyond reputedivetheworld has a reputation beyond reputedivetheworld has a reputation beyond reputedivetheworld has a reputation beyond reputedivetheworld has a reputation beyond repute
Send a message via Skype™ to divetheworld
Re: How We Wired All 3 Cells Into The Sheawater

An excellent write up, thanks Jeff.


John & Brent
__________________
Self praise is no reccomendation. Dont try to be a great man, just be a man and let history be the judge of you.
CHECK OUT OUR INTERWEBS FOR CUSTOM REBREATHER UPGRADES
Supporting Shearwater Research Products in Europe
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 23rd April 2008, 12:38   #7 (permalink)
New Member
 
Meng_Tze's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
 
Join Date: Jan 2007
Location: FL, USA
Posts: 82
Meng_Tze will become famous soon enoughMeng_Tze will become famous soon enoughMeng_Tze will become famous soon enough
Re: How We Wired All 3 Cells Into The Sheawater

Is it me or does it look like cell 1 and 3 are in reverse display when you look at both hand sets? Just something I noticed. It could be coincidence that the values are exactly the same in reverse when read out on both handsets, or they are connected in reverse.
__________________
Homo Bonae Voluntatis
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 23rd April 2008, 22:25   #8 (permalink)
New Member
 
jkeep's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
Inspiration Classic
Inspiration Vision
Megalodon
 
Join Date: Feb 2007
Location: UK
Posts: 48
jkeep is on a distinguished roadjkeep is on a distinguished road
Re: How We Wired All 3 Cells Into The Sheawater

Meng Tez,

You know to much haha Yes the readings
are back to front but that is purely down to
my good self.
When I sent the wireing plans to John Routly
I didnt put which wire went to which cell so
it ended up back to front.
John is now fully aware so anymore will be in
the correct order.

As for price..... a bloody fortune in development
haha but now that its all sorted, anybody who
wants to do it will find that it costs about £90
for the cable from John and about £40 for the
adapter from Andy.

Regards,

Jeff
__________________
Practice, Practice, Practice And Become A Master Of Technique .............
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 23rd April 2008, 22:29   #9 (permalink)
New Member
 
jkeep's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
Inspiration Classic
Inspiration Vision
Megalodon
 
Join Date: Feb 2007
Location: UK
Posts: 48
jkeep is on a distinguished roadjkeep is on a distinguished road
Re: How We Wired All 3 Cells Into The Sheawater

Plus Postage
__________________
Practice, Practice, Practice And Become A Master Of Technique .............
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 23rd April 2008, 22:51   #10 (permalink)
All The Gear, No Idea
 
windymiller's Avatar

Current Rebreather/s:
Inspiration Classic
Evolution
Megalodon

Other Rebreather/s:
 
Join Date: Oct 2005
Location: england
Posts: 203
windymiller is on a distinguished roadwindymiller is on a distinguished road
Re: How We Wired All 3 Cells Into The Sheawater

Ok, so what bits come from where?

Where do I get the adaptor?

(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



RebreatherWorld.Com ©2005 - 2008 Scuba Flair Limited
Rebreather World, Rebreather World and the Rebreather World Logo are Trademarks
All rights reserved, no republishing of content without written permission.
By using this website you have agreed to our Terms & Conditions of Use

Search Engine Optimization by vBSEO 3.1.0