![]() ![]() ![]() ![]() ![]() ![]() ![]() | Megalodon software problem help needed! Hi All I have a student taking a meg course and we have a problem with his secondary handset. During calibration the handset reads the correct Mv in air and then reads the correct Mv on O2, once the data is saved it reverts back to po2 display but reads 21% instead of 98% the three readouts are now frozen, as anyone any ideas on what could cause this? Thanks
__________________ Mathew Partridge Technical Director Pro-Tech Dive College www.protechdivers.com www.tech-ccr.com |
| (Online) | |
| | #2 (permalink) |
| Dave Tomblin ![]() ![]() Current Rebreather/s: Megalodon Other CCR Other Rebreather/s: Not Bought Yet Inspiration Classic Sport Kiss Other CCR Join Date: Feb 2005 Location: Vancouver Island BC Canada
Posts: 1,444
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: Megalodon software problem help needed! Hi All What is the battery voltage? Are the sensor contacts all solid? Do the voltages change when you wiggle the contacts?I have a student taking a meg course and we have a problem with his secondary handset. During calibration the handset reads the correct Mv in air and then reads the correct Mv on O2, once the data is saved it reverts back to po2 display but reads 21% instead of 98% the three readouts are now frozen, as anyone any ideas on what could cause this? Thanks I am just throwing out guesses here until someone way smarter comes along but I think it is more likely a mechanical/voltage issue than a software issue.
__________________ Cheers, Dave.... Man is the only animal burdened with the knowledge he will eventually die |
| (Offline) | |
| | #3 (permalink) |
| RebreatherWorld Sponsor ![]() Current Rebreather/s: Inspiration Classic Inspiration Vision Evolution Megalodon Ouroboros Dolphin Other Rebreather/s: Not Bought Yet Dolphin Join Date: May 2005 Location: Phuket, Thailand
Posts: 462
![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: Megalodon software problem help needed! What is the battery voltage? Are the sensor contacts all solid? Do the voltages change when you wiggle the contacts? SensorsMv change when O2 blown through head, Battery Mv 7.1, tried with new batterys, -+& fine only the three po2 are frozen.I am just throwing out guesses here but I think it is more likely a mechanical/voltage issue than a software issue. double check Hud is not reading correct it reads .21 8 blinks red, even when o2 is flushed through. cheers
__________________ Mathew Partridge Technical Director Pro-Tech Dive College www.protechdivers.com www.tech-ccr.com Last edited by tecdivertraining : 25th February 2007 at 03:31. |
| (Online) | |
| | #4 (permalink) |
| Dave Tomblin ![]() ![]() Current Rebreather/s: Megalodon Other CCR Other Rebreather/s: Not Bought Yet Inspiration Classic Sport Kiss Other CCR Join Date: Feb 2005 Location: Vancouver Island BC Canada
Posts: 1,444
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: Megalodon software problem help needed! SensorsMv change when O2 blown through head, Battery Mv 7.1, tried with new batterys, -+& fine only the three po2 are frozen. When O2 is flushed what mv reading are you getting. What % of O2 have you set it to calibrate to?double check Hud is not reading correct it reads .21 8 blinks red, even when o2 is flushed through. cheers
__________________ Cheers, Dave.... Man is the only animal burdened with the knowledge he will eventually die |
| (Offline) | |
| | #5 (permalink) |
| New Member Current Rebreather/s: | Re: Megalodon software problem help needed! SensorsMv change when O2 blown through head, Battery Mv 7.1, tried with new batterys, -+& fine only the three po2 are frozen. double check Hud is not reading correct it reads .21 8 blinks red, even when o2 is flushed through. cheers Matt, It sounds to me to be software problem as the cells are wired in to both hand sets, so if the primary is reading fine then the secondary must have a fault. The best course of action would be to call Steve at ISC and explain the problem to him.
__________________ Cheers Andy Mumford TDI Megalodon Instructor www.megalodon-uk.com www.deepdiving.co.uk |