It appears you have not yet registered with our community. To register for free click here
Rebreather World
       
Go Back Rebreather World Rebreathers, Components and Accessories Closed Circuit Rebreathers Megalodon Rebreather

Megalodon software problem help needed!



Reply
 
LinkBack Thread Tools Display Modes
Old 25th February 2007, 02:47   #1 (permalink)
RebreatherWorld Sponsor
 
tecdivertraining's Avatar

Current Rebreather/s:
Inspiration Classic
Inspiration Vision
Evolution
Megalodon
Ouroboros
Dolphin

Other Rebreather/s:
Not Bought Yet
Dolphin
 
Join Date: May 2005
Location: Phuket, Thailand
Posts: 462
tecdivertraining is a jewel in the roughtecdivertraining is a jewel in the roughtecdivertraining is a jewel in the roughtecdivertraining is a jewel in the roughtecdivertraining is a jewel in the roughtecdivertraining is a jewel in the roughtecdivertraining is a jewel in the rough
Megalodon software problem help needed!

Hi All

I have a student taking a meg course and we have a problem with his secondary handset. During calibration the handset reads the correct Mv in air and then reads the correct Mv on O2, once the data is saved it reverts back to po2 display but reads 21% instead of 98% the three readouts are now frozen, as anyone any ideas on what could cause this?

Thanks
__________________
Mathew Partridge
Technical Director
Pro-Tech Dive College
www.protechdivers.com
www.tech-ccr.com
(Online)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 25th February 2007, 03:14   #2 (permalink)
Dave Tomblin

 
wedivebc's Avatar

Current Rebreather/s:
Megalodon
Other CCR

Other Rebreather/s:
Not Bought Yet
Inspiration Classic
Sport Kiss
Other CCR
 
Join Date: Feb 2005
Location: Vancouver Island BC Canada
Posts: 1,444
wedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to all
Re: Megalodon software problem help needed!

Quote: (Originally Posted by tecdivertraining) View Original Post
Hi All

I have a student taking a meg course and we have a problem with his secondary handset. During calibration the handset reads the correct Mv in air and then reads the correct Mv on O2, once the data is saved it reverts back to po2 display but reads 21% instead of 98% the three readouts are now frozen, as anyone any ideas on what could cause this?

Thanks
What is the battery voltage? Are the sensor contacts all solid? Do the voltages change when you wiggle the contacts?
I am just throwing out guesses here until someone way smarter comes along but I think it is more likely a mechanical/voltage issue than a software issue.
__________________
Cheers,

Dave....

Man is the only animal burdened with the knowledge he will eventually die
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 25th February 2007, 03:18   #3 (permalink)
RebreatherWorld Sponsor
 
tecdivertraining's Avatar

Current Rebreather/s:
Inspiration Classic
Inspiration Vision
Evolution
Megalodon
Ouroboros
Dolphin

Other Rebreather/s:
Not Bought Yet
Dolphin
 
Join Date: May 2005
Location: Phuket, Thailand
Posts: 462
tecdivertraining is a jewel in the roughtecdivertraining is a jewel in the roughtecdivertraining is a jewel in the roughtecdivertraining is a jewel in the roughtecdivertraining is a jewel in the roughtecdivertraining is a jewel in the roughtecdivertraining is a jewel in the rough
Re: Megalodon software problem help needed!

Quote: (Originally Posted by wedivebc) View Original Post
What is the battery voltage? Are the sensor contacts all solid? Do the voltages change when you wiggle the contacts?
I am just throwing out guesses here but I think it is more likely a mechanical/voltage issue than a software issue.
SensorsMv change when O2 blown through head, Battery Mv 7.1, tried with new batterys, -+& fine only the three po2 are frozen.

double check Hud is not reading correct it reads .21 8 blinks red, even when o2 is flushed through.

cheers
__________________
Mathew Partridge
Technical Director
Pro-Tech Dive College
www.protechdivers.com
www.tech-ccr.com

Last edited by tecdivertraining : 25th February 2007 at 03:31.
(Online)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 25th February 2007, 04:27   #4 (permalink)
Dave Tomblin

 
wedivebc's Avatar

Current Rebreather/s:
Megalodon
Other CCR

Other Rebreather/s:
Not Bought Yet
Inspiration Classic
Sport Kiss
Other CCR
 
Join Date: Feb 2005
Location: Vancouver Island BC Canada
Posts: 1,444
wedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to allwedivebc is a name known to all
Re: Megalodon software problem help needed!

Quote: (Originally Posted by tecdivertraining) View Original Post
SensorsMv change when O2 blown through head, Battery Mv 7.1, tried with new batterys, -+& fine only the three po2 are frozen.

double check Hud is not reading correct it reads .21 8 blinks red, even when o2 is flushed through.

cheers
When O2 is flushed what mv reading are you getting. What % of O2 have you set it to calibrate to?
__________________
Cheers,

Dave....

Man is the only animal burdened with the knowledge he will eventually die
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 25th February 2007, 20:17   #5 (permalink)
New Member
 
AndyMumford's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
Megalodon
 
Join Date: Apr 2005
Location: Kent, UK
Posts: 81
AndyMumford is an unknown quantity at this point
Send a message via MSN to AndyMumford Send a message via Skype™ to AndyMumford
Re: Megalodon software problem help needed!

Quote: (Originally Posted by tecdivertraining) View Original Post
SensorsMv change when O2 blown through head, Battery Mv 7.1, tried with new batterys, -+& fine only the three po2 are frozen.

double check Hud is not reading correct it reads .21 8 blinks red, even when o2 is flushed through.

cheers

Matt,
It sounds to me to be software problem as the cells are wired in to both hand sets, so if the primary is reading fine then the secondary must have a fault.

The best course of action would be to call Steve at ISC and explain the problem to him.
__________________
Cheers

Andy Mumford
TDI Megalodon Instructor

www.megalodon-uk.com
www.deepdiving.co.uk
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



RebreatherWorld.Com ©2005 - 2008
Rebreather World, Rebreather World and the Rebreather World Logo are Trademarks
All rights reserved, no republishing of content without written permission.
By using this website you have agreed to our Terms & Conditions of Use

Search Engine Optimization by vBSEO 3.1.0