| | #11 (permalink) |
| Custom Title Allowed! Current Rebreather/s: Inspiration Classic Classic Kiss Other Rebreather/s: Inspiration Classic Sport Kiss Classic Kiss Join Date: Dec 2005 Location: norfolk uk
Posts: 179
![]() ![]() ![]() ![]() | Re: CK Scrubber - Gap at the bottom I would avoid doing this, you end up with the whole weight of your rig standing on the head/scrubber which is hung on just two bolts (which go into plastic) Better IMO to stand it on the CL case or foot (Narked@90 make a cracker if you need extra height) it depends on the style of boot that is used.The one i have (dont know what make it is) still gives clearence so that the unit is still standing on the cl case.However your quite right in saying that the Narked@90 stand sorts out that problem, and is a nice bit of kit.Ray ![]() |
| (Offline) | |
| | #12 (permalink) |
| I go down for ages ![]() Current Rebreather/s: Classic Kiss Other Rebreather/s: Inspiration Classic Join Date: Jan 2005 Location: Kent
Posts: 2,700
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: CK Scrubber - Gap at the bottom Many thanks for posting this. I just unpacked my KISS and shoved two plastic wedges under the scrubber to support it in transit ![]() ATB Mark Chase
__________________ Is it supposed to make that noise ? ![]() I took my unit to the dive shop and demanded they bolt on every thing that would fit. ![]() Join my elite diving teem and get a Tshirt "Doing It Chasey"Hammerhead Eccr Advanced Diving System |
| (Offline) | |
| | #13 (permalink) |
| Better Off Out of the EU Current Rebreather/s: Classic Kiss Other Rebreather/s: Join Date: Nov 2005 Location: Great Britain
Posts: 387
![]() ![]() ![]() ![]() | Re: CK Scrubber - Gap at the bottom Or alternatively use upright tanks and the weight of the unit is held by the tank bottoms, not the scrubber can.... The stand isn't my cup of tea at all (sorry John).![]() [I get my coat...] I have considered de-inverting the tanks. It would be good to see some photos or maybe an article on the pro/cons and what bits you need to do it neatly.
__________________ "dove" is NOT the past tense of "dive" Better off OUT of the EU ! www.hugsac.org.uk |
| (Offline) | |
| | #16 (permalink) |
| New Member Current Rebreather/s: Classic Kiss Other Rebreather/s: Join Date: Jun 2006 Location: Perth
Posts: 91
![]() ![]() ![]() | Re: CK Scrubber - Gap at the bottom The stand isn't my cup of tea at all (sorry John). Check Cedric Verdier's website. I believe he has written an article on deinverting tanks.I have considered de-inverting the tanks. It would be good to see some photos or maybe an article on the pro/cons and what bits you need to do it neatly.
__________________ Classic KISS #271 |
| (Offline) | |
| | #17 (permalink) |
| Custom Title Allowed! Current Rebreather/s: Inspiration Classic Classic Kiss Other Rebreather/s: Inspiration Classic Sport Kiss Classic Kiss Join Date: Dec 2005 Location: norfolk uk
Posts: 179
![]() ![]() ![]() ![]() | Re: CK Scrubber - Gap at the bottom [quote] On a similar note, my wing hangs below the CL case so it tends to sit on the wing. Does everyone have this problem ?QUOTE] i have the posidon besa wing, as it is deep rather than long ,so that it is the same length as the scrubber case. works greatRay ![]() |
| (Offline) | |