| | #1 (permalink) |
| RBW Member Current Rebreather/s: Other CCR Other Rebreather/s: Inspiration Classic Inspiration Vision Other CCR Join Date: Nov 2005 Location: espoo, finland
Posts: 29
| Temp stick problem I was on a 5 day safari on the red sea had little problem with the temp stick. (See profile as an attachment) at 4min to the dive the scrubber monitor goes plank and was showing on the hand set only -----. I re-started the unit on the surface and scrubber was on line again. Wondering what might cause this? I'v had this happen to me on repeated diving days even if i have dried the head and the hole canister really carefully between dives. Cables were connected properly and there is no corosion on the wires or connectors. Has anyone else had this problem? -Mikko |
| (Offline) | |
| | #3 (permalink) |
| RBW Member Current Rebreather/s: Other CCR Other Rebreather/s: Inspiration Classic Inspiration Vision Other CCR Join Date: Nov 2005 Location: espoo, finland
Posts: 29
| Re: Temp stick problem I've sent the profile to ambient pressure and they said it looked like a poor connection and asked to check the wires and connectors for corrosion and see if wiggling the wires has any affect on the connection... it didn’t so decided to ask around here if anyone has had any similar problems |
| (Offline) | |