help needed

HI all last week i got a used inspiration and now doing my mod-1,when i got it the di/o2 hose and contents gauges where on the out side of the counter lungs and it fitted great ( not tight around my neck ) and now on mod-1 my instructor has told me to run them on the inside of the counter lungs making it tight around my neck so whats the best or right way to do it?

also it will not hold a pos/neg pressure test and my instructor say it never will with the ADV fitted is that right? ( inspiration 9 months old )
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 29th October 2006, 20:35   #2 (permalink)
Custom Title Allowed!
 
jhaaja's Avatar

Current Rebreather/s:
Inspiration Classic

Other Rebreather/s:
 
Join Date: Mar 2005
Location: Finland
Posts: 885
jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice
Re: help needed

Quote: (Originally Posted by gary maidment) View Original Post
HI all last week i got a used inspiration and now doing my mod-1,when i got it the di/o2 hose and contents gauges where on the out side of the counter lungs and it fitted great ( not tight around my neck ) and now on mod-1 my instructor has told me to run them on the inside of the counter lungs making it tight around my neck so whats the best or right way to do it?

also it will not hold a pos/neg pressure test and my instructor say it never will with the ADV fitted is that right? ( inspiration 9 months old )
I say it is up to you which ones you want to run on the inside. On my unit the HP-gaugehoses are on the inner side and LP-hoses on the outer side.

The adv will leak if you do not have a flow stop fitted. With flow stop you can do a proper neg. andpos.

JH
Finland
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 29th October 2006, 20:39   #3 (permalink)
New Member
 
gary maidment's Avatar

Current Rebreather/s:
Inspiration Classic

Other Rebreather/s:
 
Join Date: Sep 2006
Location: durham uk
Posts: 22
gary maidment is an unknown quantity at this point
Re: help needed

hi i do have a flow stop on it is it best to try it with it closed?
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 29th October 2006, 21:03   #4 (permalink)
RBW Member
 
diverklondike's Avatar

Current Rebreather/s:
Inspiration Classic
Other CCR

Other Rebreather/s:
Inspiration Classic
Other CCR
 
Join Date: Oct 2005
Location: Delaware, USA
Posts: 1,699
diverklondike has a reputation beyond repute diverklondike has a reputation beyond repute diverklondike has a reputation beyond repute diverklondike has a reputation beyond repute diverklondike has a reputation beyond repute diverklondike has a reputation beyond repute diverklondike has a reputation beyond repute diverklondike has a reputation beyond repute diverklondike has a reputation beyond repute diverklondike has a reputation beyond repute diverklondike has a reputation beyond repute
Re: help needed

Quote: (Originally Posted by gary maidment) View Original Post
hi i do have a flow stop on it is it best to try it with it closed?
Correct...
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 30th October 2006, 07:17   #5 (permalink)
Nick Cunningham-Moorat
 
scunick's Avatar

Current Rebreather/s:
Other CCR

Other Rebreather/s:
Inspiration Classic
Inspiration Vision
Other CCR
 
Join Date: Jun 2005
Location: South Africa - Cape Town
Posts: 109
scunick has a spectacular aura about scunick has a spectacular aura about scunick has a spectacular aura about scunick has a spectacular aura about scunick has a spectacular aura about scunick has a spectacular aura about
Re: help needed

Quote: (Originally Posted by jhaaja) View Original Post
I say it is up to you which ones you want to run on the inside. On my unit the HP-gaugehoses are on the inner side and LP-hoses on the outer side.

The adv will leak if you do not have a flow stop fitted. With flow stop you can do a proper neg. andpos.

JH
Finland
Ditto on the config. With the ADV fitted and the Flow stop engaged I am able to do both pos and neg tests without a problem. (PS my unit is 4 months old)
Cheers
Nick
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 30th October 2006, 07:35   #6 (permalink)
aki
Inspiration Vision Diver
 
aki's Avatar

Current Rebreather/s:
Inspiration Vision
Megalodon

Other Rebreather/s:
 
Join Date: Oct 2005
Location: Stockholm. Sweden
Posts: 117
aki will become famous soon enough aki will become famous soon enough aki will become famous soon enough
Send a message via MSN to aki Send a message via Skype™ to aki
Re: help needed

Quote: (Originally Posted by scunick) View Original Post
Ditto on the config. With the ADV fitted and the Flow stop engaged I am able to do both pos and neg tests without a problem. (PS my unit is 4 months old)
Cheers
Nick
Same here on the config and if you don't have a Flow Stop you can always keep the diluent bottle closed prior to the test so that ADV cannot operate.
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 30th October 2006, 08:22   #7 (permalink)
Custom Title Allowed!
 
Barrie Law's Avatar

Current Rebreather/s:
Inspiration Classic

Other Rebreather/s:
 
Join Date: Jun 2005
Location: Ireland
Posts: 459
Barrie Law is a glorious beacon of light Barrie Law is a glorious beacon of light Barrie Law is a glorious beacon of light Barrie Law is a glorious beacon of light Barrie Law is a glorious beacon of light Barrie Law is a glorious beacon of light Barrie Law is a glorious beacon of light Barrie Law is a glorious beacon of light Barrie Law is a glorious beacon of light Barrie Law is a glorious beacon of light Barrie Law is a glorious beacon of light
Send a message via Skype™ to Barrie Law
Re: help needed

Quote: (Originally Posted by gary maidment) View Original Post
HI all last week i got a used inspiration and now doing my mod-1,when i got it the di/o2 hose and contents gauges where on the out side of the counter lungs and it fitted great ( not tight around my neck ) and now on mod-1 my instructor has told me to run them on the inside of the counter lungs making it tight around my neck so whats the best or right way to do it?

also it will not hold a pos/neg pressure test and my instructor say it never will with the ADV fitted is that right? ( inspiration 9 months old )
Hi Gary,

Good luck with your MOD 1 course, discuss the fact you find the hose's feel tight when fitted on the inside and see how they can be routed more comfortably.

Your Instructor will have a look at this with you and sort it out remember he is not an obstacle to get around rather a mentor who is sharing his experience to give you the basic knowledge and also the confidence to use your Inspiration safely.

Positive and Negative loop checks are a fundamental part of the Inspiration Pre-Dive check routine and must be done before every dive, I do not believe there is an instructor out there who would not know how to do this blindfolded.

Regards
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 30th October 2006, 22:43   #8 (permalink)
New Member
 
gary maidment's Avatar

Current Rebreather/s:
Inspiration Classic

Other Rebreather/s:
 
Join Date: Sep 2006
Location: durham uk
Posts: 22
gary maidment is an unknown quantity at this point
Re: help needed

Thanks again all had it in the pool and it looks as if the ADV is bust my instructor (Bob) is going to have a look at it and tells me to get shot of the ADV and get a T-piece and use my finger


any one got a T-piece for sale
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 31st October 2006, 05:27   #9 (permalink)
Old Member
 
GuyW's Avatar

Current Rebreather/s:
Inspiration Classic

Other Rebreather/s:
 
Join Date: Apr 2006
Location: Sydney, Australia
Posts: 61
GuyW has a spectacular aura about GuyW has a spectacular aura about GuyW has a spectacular aura about GuyW has a spectacular aura about GuyW has a spectacular aura about
Re: help needed

Quote: (Originally Posted by gary maidment) View Original Post
Thanks again all had it in the pool and it looks as if the ADV is bust my instructor (Bob) is going to have a look at it and tells me to get shot of the ADV and get a T-piece and use my finger
any one got a T-piece for sale
Why not fix it ? They are not that complex and are quite useful.

Guy
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 31st October 2006, 06:12   #10 (permalink)
Custom Title Allowed!
 
jhaaja's Avatar

Current Rebreather/s:
Inspiration Classic

Other Rebreather/s:
 
Join Date: Mar 2005
Location: Finland
Posts: 885
jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice jhaaja is just really nice
Re: help needed

I have one Bob Howell ADV for sale. Offer something
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



RebreatherWorld.Com ©2005 - 2008
Rebreather World, RBW and the Rebreather World Logo are Trademarks
All rights reserved, no republishing of content without written permission.
By using this website you have agreed to our Terms & Conditions of Use

Search Engine Optimization by vBSEO 3.1.0

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413