| | #1 (permalink) |
| New Member Current Rebreather/s: Inspiration Classic Other Rebreather/s: Join Date: May 2005 Location: Malta
Posts: 38
| O2 warning on Slave Hi Guys, Last weekend during deco in 6 mtrs whilst pushing my cells to 1.6 as a routine check - my slave began to show the high O2 warning but the master did not , only when I pushed slightly higer set point did the master kick off and the audible alarm go off, any suggestions why ,and if this normal ? thks Simon |
| (Offline) | |
| | #2 (permalink) |
| Nutty dentist - uwdriller Current Rebreather/s: | Re: O2 warning on Slave Hi Guys, Hi SimonLast weekend during deco in 6 mtrs whilst pushing my cells to 1.6 as a routine check - my slave began to show the high O2 warning but the master did not , only when I pushed slightly higer set point did the master kick off and the audible alarm go off, any suggestions why ,and if this normal ? thks Simon 1.6 will trigger the high O2 alarm on the inspo - if I read your post correctly the slave did show 1.6 and gave the alarm - which is correct, but what was the Master reading ? If it did read 1.6 on all cells as well I would expcet it to go to high O2, but if it did read other than the slave I would be somehoe supiscious ( hence teh slave gets the data form the mastrer calibration - or so I think?). If it did read different I would conatct AP with this problem, maybe a software bug ? Cheers christian
__________________ May The Sorb Be With You |
| (Offline) | |
| | #3 (permalink) |
| New Member Current Rebreather/s: Inspiration Classic Other Rebreather/s: Join Date: May 2005 Location: Malta
Posts: 38
| Re: O2 warning on Slave Hi Both the slave and the master were giving the same readings. But the slave was giving a high o2 warning [but obviously wihtout the audible alarm] whilst the master was not showing any alarms . If anything I would have expexted the Master to go off first anyone has had this prob Simon |
| (Offline) | |