Hi,

last Saturday I was underwater with my YBOD. First dive was with a level 2 CMAS Student and we have made some exercises (signs and reactions on signs, nothing special) in a depth of maximum 25M and a dive time of 40 minutes. Second dive, immediately after my student was out of the water we decided to make a second dive. I was with another diver (Megalodon). We went down to 20/23M and suddenly I got a cell alarm: all 3 cells on both computers... This happened as the PpO2 went high (I have it on automatic at 20M). The alarm disappeared immediately and I flushed the machine with AIR and noticed that all 3 cells were reacting similarly so I decided to continue my dive. We were down to 34 M and go for another 30 minutes without any problems.

My Inspiration Vision is brand new so new solenoid, new cells, etc

Any ideas of what happened ?

Cheers

Humuhumu
__________________
Humuhumu Nukunuku Apua'a
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 14th July 2008, 17:37   #2 (permalink)
Phil Siswick, Tango
 
PhilSiswick's Avatar

Current Rebreather/s:
Evolution

Other Rebreather/s:
Inspiration Vision
 
Join Date: Apr 2006
Location: Oxford, UK
Posts: 1,099
PhilSiswick is a splendid one to behold PhilSiswick is a splendid one to behold PhilSiswick is a splendid one to behold PhilSiswick is a splendid one to behold PhilSiswick is a splendid one to behold PhilSiswick is a splendid one to behold PhilSiswick is a splendid one to behold PhilSiswick is a splendid one to behold PhilSiswick is a splendid one to behold PhilSiswick is a splendid one to behold PhilSiswick is a splendid one to behold
Re: Strange behaviour of my Inspiration

Quote: (Originally Posted by Humuhumu) View Original Post
Hi,

last Saturday I was underwater with my YBOD. First dive was with a level 2 CMAS Student and we have made some exercises (signs and reactions on signs, nothing special) in a depth of maximum 25M and a dive time of 40 minutes. Second dive, immediately after my student was out of the water we decided to make a second dive. I was with another diver (Megalodon). We went down to 20/23M and suddenly I got a cell alarm: all 3 cells on both computers... This happened as the PpO2 went high (I have it on automatic at 20M). The alarm disappeared immediately and I flushed the machine with AIR and noticed that all 3 cells were reacting similarly so I decided to continue my dive. We were down to 34 M and go for another 30 minutes without any problems.

My Inspiration Vision is brand new so new solenoid, new cells, etc

Any ideas of what happened ?

Cheers

Humuhumu
Yes, I've had this, though usually only on one cell. One of my buddies had problems with this as well, on a brand new head. He sent it back to AP, who told him that he wasn't breathing enough :-)

Essentially, I think it comes from the rapid spike you get when you switch up the setpoint. I've found that it is more likely to happen with new cells, maybe because they are more sensitive. With a little time, they settle down.

As it's annoying (and worrying), I try to let my PO2 creep up towards my target setpoint as I reach the bottom. That way, there's no big swing in PO2meaning less bouyancy change, fewer alarms and less load on the battery.

HTH,
__________________
Phil (WSKD 0001)

I have always felt that the dive I am on is not nearly important as the dives I plan to be on the rest of my life. Tom Rose, 2007

The person who gets the farthest is generally the one who is willing to do and dare. The sure thing boat never gets far from shore. Charles A. Lindbergh

www.hugsac.org.uk

Last edited by PhilSiswick : 14th July 2008 at 20:58.
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 14th July 2008, 18:14   #3 (permalink)
Custom Title Allowed!
 
KevDD's Avatar

Current Rebreather/s:
Inspiration Vision

Other Rebreather/s:
Inspiration Classic
 
Join Date: Oct 2005
Location: Dublin, Ireland
Posts: 99
KevDD will become famous soon enough KevDD will become famous soon enough KevDD will become famous soon enough KevDD will become famous soon enough
Re: Strange behaviour of my Inspiration

It seems to be a feature of the visions
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 14th July 2008, 22:18   #4 (permalink)
Old, maybe one day wise
 
Tino de Rijk's Avatar

Current Rebreather/s:
Inspiration Vision

Other Rebreather/s:
Inspiration Classic
Evolution
 
Join Date: Mar 2006
Location: Amsterdam
Posts: 375
Tino de Rijk has a brilliant future Tino de Rijk has a brilliant future Tino de Rijk has a brilliant future Tino de Rijk has a brilliant future Tino de Rijk has a brilliant future Tino de Rijk has a brilliant future Tino de Rijk has a brilliant future Tino de Rijk has a brilliant future Tino de Rijk has a brilliant future Tino de Rijk has a brilliant future Tino de Rijk has a brilliant future
Re: Strange behaviour of my Inspiration

Quote: (Originally Posted by KevDD) View Original Post
It seems to be a feature of the visions
No it is not.
Contact the factory. It has to do with the outlet (nozzle) of the new solenoid. It typically appears when switching from low to high setpoint. The nozzle of the new solenoid then causes a small "whirlwind" which causes a small "bubble" of O2 to temporarily stick with the cells.
APD has developed a better nozzle that causes a better mix in the scruber head, supposedly getting rid of this nuisance.
MartinP from APD wrote about this on the Inspo mailing list a week ago or so.
contact the factory to see if this is your problem. If so, it's easily fixed.
Untill that time, it is not a worrying feature: it only occurs when the solenoid opens a long time (as in switching from low to high setpoint), and it is just a bubble of O2 sitting at the cells temporarily (as in: a few seconds).
It doesn't mean you actually breath that high PO2, as the bubble gets diluted in C/L and hose before it reaches the mouthpiece. Even if you were to breath it, that would only be for a few seconds.
So nuisance, not danger.
But check with APD to be sure: my info is based on hear-say, albeit well informed hear-say... :-)

Ciao,

Tino.
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 15th July 2008, 11:53   #5 (permalink)
Yellow Box Of Delight
 
Humuhumu's Avatar

Current Rebreather/s:
Inspiration Vision

Other Rebreather/s:
Not Bought Yet
 
Join Date: Jan 2007
Location: Blue Planet
Posts: 147
Humuhumu has a little shameless behaviour in the past
Re: Strange behaviour of my Inspiration

Thank you guys it's good to hear that you have experienced the same. In fact I was not anxious as I get control of the situation quickly. I will mail to APD to fix the problem.

Cheers

Humuhumu
__________________
Humuhumu Nukunuku Apua'a
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 18th July 2008, 19:36   #6 (permalink)
New Member
 
intouch1's Avatar

Current Rebreather/s:
Evolution

Other Rebreather/s:
 
Join Date: Sep 2007
Location: Red Sea
Posts: 13
intouch1 is an unknown quantity at this point
Re: Strange behaviour of my Inspiration

its' just annoying I guess as these alarms do grab your focus and attention.
mine on a brand new Evo with less than 15 hours dive time is giving me cell warnings on a single cell as well. i also usually have a cell that is a bit behind the other two.....
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 19th July 2008, 14:46   #7 (permalink)
Yellow Box Of Delight
 
Humuhumu's Avatar

Current Rebreather/s:
Inspiration Vision

Other Rebreather/s:
Not Bought Yet
 
Join Date: Jan 2007
Location: Blue Planet
Posts: 147
Humuhumu has a little shameless behaviour in the past
Re: Strange behaviour of my Inspiration

Hi,

had the same problem this morning. It happens always when you go on the high set point. I had a very short cell alarm, just on the vision, no buzzer, so very very fast. My PpO2 climbed to 1,45 and so it's not a problem (I can do with 2 for a moment, I had to in the past with my special Dolphin :-). After a second it was back down to 1,2, that's a prove that it's a problem in relation with the new solenoid. APD have offered me to analyze the logs to see how they can fix this, but I'm confident, the problem is well know, their service is excellent, so this should all be fixed shortly.

Cheers

Humuhumu
__________________
Humuhumu Nukunuku Apua'a
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 28th July 2008, 20:59   #8 (permalink)
New Member
 
aborigene's Avatar

Current Rebreather/s:
Inspiration Classic
Inspiration Vision

Other Rebreather/s:
 
Join Date: Jan 2008
Location: Bandol (south of France)
Posts: 8
aborigene is an unknown quantity at this point
Re: Strange behaviour of my Inspiration

Hi,
Tino , what do you mean by "APD has developed a better nozzle" ? Do you mean that a spare exists ?
thank you
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 29th July 2008, 13:17   #9 (permalink)
still learning...
 
gallathan's Avatar

Current Rebreather/s:
Inspiration Classic
Inspiration Vision

Other Rebreather/s:
 
Join Date: Mar 2006
Location: Laleham, Middlesex, England, UK
Posts: 68
gallathan is just really nice gallathan is just really nice gallathan is just really nice gallathan is just really nice gallathan is just really nice gallathan is just really nice gallathan is just really nice gallathan is just really nice gallathan is just really nice gallathan is just really nice gallathan is just really nice
Re: Strange behaviour of my Inspiration

I emailed Nicky @ AP, and they sent me a new / replacement nozzle for the new solenoid, free of charge. Looks different / sounds different / easy to fit. Definitely improved the issue, so problem with 20+ dives on it so far...
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Old 14th August 2008, 20:45   #10 (permalink)
Yellow Box Of Delight
 
Humuhumu's Avatar

Current Rebreather/s:
Inspiration Vision

Other Rebreather/s:
Not Bought Yet
 
Join Date: Jan 2007
Location: Blue Planet
Posts: 147
Humuhumu has a little shameless behaviour in the past
Re: Strange behaviour of my Inspiration

Hi,

I have sent my new logs (6) to Zoe. I still have the same problems. I have made a dive on the "TOGO" (a wreck near Cavalaire 50 to 55 and more) and had also a problem while ascending. In fact I had to assist the diver who was with me and lost 0,6M, that produced a "high oxygen" alarm (setpoint 1,4 --> over 1,6) ! I'm waiting for some inputs from APD.

As I have made some dives with other YBOD users (classics) I can say, they didn't have the same problems.

Anyway great unit, I'm very happy to have made this choice, after 2 years with my Dolphin !

Cheers

Humuhumu
__________________
Humuhumu Nukunuku Apua'a
(Offline)
 
Digg this Post!Add Post to del.icio.us
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On



RebreatherWorld.Com ©2005 - 2008
Rebreather World, RBW and the Rebreather World Logo are Trademarks
All rights reserved, no republishing of content without written permission.
By using this website you have agreed to our Terms & Conditions of Use

Search Engine Optimization by vBSEO 3.1.0

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432