| | #1 (permalink) |
| Cheif tea maker ![]() ![]() Current Rebreather/s: | Published Inspiration / Evolution WOB APD have just released the work of breathing figures for the Inspiration and Evolution on the website. These are figures verified by an independent 3rd Party - SGS Yarlsey - the company that we and most of the main diving companies use for CE certification. See the downloads: Inspiration Evolution From: Ambient Pressure Diving Ltd.
__________________ Beanie Gallery Admin & Library Assistant. www.outlawdivers.org.uk www.beandiving.co.uk www.beanengineering.co.uk www.divelife.co.uk |
| (Offline) | |
| | #3 (permalink) |
| Custom Title Allowed! Current Rebreather/s: | Re: Published Inspiration / Evolution WOB Hi, I personally hope that other manufacturers that would publish same data as well. Best Regards. Wael
__________________ The depth of life cannot be measured in Bars, nor can the sea of lies, that lies within. I don't take crap for an answer... |
| (Offline) | |
| | #4 (permalink) |
| New Member ![]() Current Rebreather/s: | Re: Published Inspiration / Evolution WOB Interesting how little difference there is between them when there is a couple of inches off the scrubber. Clearly the 'lime is virtually trivial to WOB. I wouldn't have guessed that.
__________________ nigelh |
| (Online) | |
| | #5 (permalink) |
| Cheif tea maker ![]() ![]() Current Rebreather/s: | Re: Published Inspiration / Evolution WOB Interesting how little difference there is between them when there is a couple of inches off the scrubber. I don't know if it makes a difference but the inspiration is noted as vertical but the orientation of the Evolution isn't noted.Clearly the 'lime is virtually trivial to WOB. I wouldn't have guessed that.
__________________ Beanie Gallery Admin & Library Assistant. www.outlawdivers.org.uk www.beandiving.co.uk www.beanengineering.co.uk www.divelife.co.uk |
| (Offline) | |
| | #6 (permalink) |
| Moderator ![]() ![]() Current Rebreather/s: Inspiration Classic Sport Kiss Optima rEvo Other CCR Home Build Other Rebreather/s: Inspiration Vision Evolution Megalodon Classic Kiss rEvo Other CCR Home Build Join Date: Mar 2005 Location: "Da" Bronx
Posts: 2,795
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: Published Inspiration / Evolution WOB it would be nice if AP published the lissajou cycle and calibration data since the results look to be about half of what Alex says his company tested it at.. The shape of Alex's curve looks correct.. APs chart does not allow us to see the actual test results.. if they are really different not just displaying the data differently, why is there such a discrepency?? AP's numbers are fairly close to Alex's peak WOB (pos or neg) but not total wob... The posting of this data brings up more questions than it answers.. Alex says runs tests with an exhausted scrubber for worse case.. How did AP test it?? Does it make that much of a difference??
__________________ Joe Radomski CCR Trimix Instructor Trainer ANDI Instructor Trainer Director #10 All posts are personal opinions and DO NOT reflect any affiliated agency unless specifically stated. |
| (Offline) | |