| | #1 (permalink) |
| IDA-71,IDA-76,NaubosAR90 Current Rebreather/s: Other CCR Other Rebreather/s: Not Bought Yet Other CCR Join Date: Oct 2006 Location: Italia - Sicilia
Posts: 248
| automatic add diluent valve Hello can I use a normal 2'nd stage regulator as an automati add valve? Regards Giovanni |
| (Offline) | |
| | #2 (permalink) |
| Stéphane Acounis Current Rebreather/s: rEvo Other Rebreather/s: rEvo Join Date: Nov 2005 Location: Nantes - France
Posts: 788
| Re: automatic add diluent valve Hi, Yes, why not, but you'll have to block the exhaust valve otherwise you will loose all your gas. Have a look at the first photos in this album: Ouverture de session Yahoo! - Création de compte
__________________ Stéphane |
| (Offline) | |
| | #3 (permalink) |
| IDA-71,IDA-76,NaubosAR90 Current Rebreather/s: Other CCR Other Rebreather/s: Not Bought Yet Other CCR Join Date: Oct 2006 Location: Italia - Sicilia
Posts: 248
| Re: automatic add diluent valve Thanks...... I have done an experiment but don't close the exhaust valve... ![]() I think that is maybe the problem.. ..the conterlung is always empty... ![]() I hope to use the exaust vale of 2d stage as exsaust valve but...is to simple to work... i use a adjustable valve ![]() |
| (Offline) | |
| | #4 (permalink) |
| hell is in the details Current Rebreather/s: RB80 / Clone Home Build Other Rebreather/s: Not Bought Yet RB80 / Clone Home Build Join Date: Sep 2005 Location: FRANCE Carcassonne
Posts: 498
| Re: automatic add diluent valve Thanks...... I have done an experiment but don't close the exhaust valve... ![]() I think that is maybe the problem.. ..the conterlung is always empty... ![]() I hope to use the exaust vale of 2d stage as exsaust valve but...is to simple to work... i use a adjustable valve ![]() Hi, I use that on some of my home-made Rebreather after a friend got the same idea. Take a back up 2nd stage from aqualung, the exhaust valve is just behind a grid you can take out without tool, put a disc then a spring then again the grid and you got a wonderfull non expensive ADV with built in exhaust valve. It worked fine several hundred hours without any prob. Its not too simple just simple as Christophe Colomb egg as we say in France With that you can build a Rebreather in few seconds cheers Marc |
| (Offline) | |
| | #5 (permalink) |
| IDA-71,IDA-76,NaubosAR90 Current Rebreather/s: Other CCR Other Rebreather/s: Not Bought Yet Other CCR Join Date: Oct 2006 Location: Italia - Sicilia
Posts: 248
| Re: automatic add diluent valve good idea...but need a 2d stage with grid...and....a correct spring.....mmmmmmmm good idea! ![]() |
| (Offline) | |
| | #6 (permalink) |
| Custom Title Allowed! Current Rebreather/s: Home Build Other Rebreather/s: Sport Kiss Home Build Join Date: Feb 2005 Location: Brisbane, QLD, Australia
Posts: 239
| Re: automatic add diluent valve The adv in my converted azi is a aqualung occy mechanism in a different body. So to answer, yes if set up properly. Matt |
| (Offline) | |