| | #1 (permalink) |
| New Member Current Rebreather/s: Optima Other Rebreather/s: Join Date: Jul 2006 Location: Weeki Wachee, Fl.
Posts: 24
![]() | vr3 calibration issues Anyone have any suggestions for calibrating the Vr3 to read po2 via and external cell...I have tried 2 different cells both new, but the VR3 will not read anything lower than 30% o2 in ambient air? Nick |
| (Offline) | |
| | #2 (permalink) |
| RebreatherWorld Sponsor ![]() ![]() Current Rebreather/s: | Re: vr3 calibration issues Anyone have any suggestions for calibrating the Vr3 to read po2 via and external cell...I have tried 2 different cells both new, but the VR3 will not read anything lower than 30% o2 in ambient air? Hi Nick,Nick Have you calibrated the Cell in 100% (.99) Oxygen? You need to switch the Cal gas (100%) on to perform the Cell calibration and flush with Oxygen to achieve a stable reading. Remember to switch it off again after you have completed the Calibration Process and return the Vr3 to your dive gas selection. You could look here for further info; http://www.rebreatherworld.com/attac...rebreather.pdf Regards
__________________ Barrie Law Rebreather World Store Supplying the Rebreather World Tel:US +19548403892 Fax:US+19543333792 Tel:EU+442071930496 Fax:EU+442077606344 Mobile+353876880628 Skype:barrielaw Email: barrie@rebreatherworldstore.com |