![]() ![]() ![]() ![]() ![]() ![]() | I would like some input............ I just had my head serviced and that included fresh cells. On the last two dives the cells were calibrated prior to the dives and slowly over the course of the dive were reading farther and farther off of the set point. At one point on the second dive I got a cell warning on the hand set (this ended the dive). Just wondering if anyone has had this happen to them. The issue has been reported to SDS and they should get back to me tomorrow. Rob |
| (Online) | |
| | #2 (permalink) |
| Custom Title Allowed! Current Rebreather/s: Inspiration Vision Other Rebreather/s: Inspiration Classic Join Date: Feb 2005 Location: London, UK
Posts: 303
![]() ![]() ![]() ![]() ![]() ![]() ![]() ![]() | Re: Cell Warning! I've had a couple of cells that seemed to loose calibration on longer dives, drifted to 0.2 below other cells. O2 flush at 6m & they only made it to 1.4. Once head dried out, they calibrated OK & worked OK for 90mins to 2 hours. When doing 2 dives, cell caused "must calibration" when unit turned on for 2nd dive rather than the more usual "calibrate?". However, more noticeable on longer 3 hour dives. One cell replaced by AP, the other is currently in my spares kit. Replacing cell fixed issue. Hope this helps JT |
| (Online) | |
| | #3 (permalink) |
| The Evolution of Diving Current Rebreather/s: Evolution Other SCR Other Rebreather/s: Not Bought Yet Other SCR Join Date: May 2005 Location: Victoria BC Canada
Posts: 315
![]() ![]() ![]() ![]() ![]() ![]() | Re: Cell Warning! I've had a couple of cells that seemed to loose calibration on longer dives, drifted to 0.2 below other cells. O2 flush at 6m & they only made it to 1.4. Once head dried out, they calibrated OK & worked OK for 90mins to 2 hours. Thanks for the info. I am hoping that AP will replace the cells and that will be all that is needed. Should here back tomorrowWhen doing 2 dives, cell caused "must calibration" when unit turned on for 2nd dive rather than the more usual "calibrate?". However, more noticeable on longer 3 hour dives. One cell replaced by AP, the other is currently in my spares kit. Replacing cell fixed issue. Hope this helps JT Rob |
| (Online) | |
| | #4 (permalink) |
| New Member Current Rebreather/s: Inspiration Classic Other Rebreather/s: Join Date: Jun 2006 Location: Melbourne, Australia
Posts: 91
![]() ![]() ![]() ![]() ![]() | Re: Cell Warning! I've had a couple of cells that seemed to loose calibration on longer dives, drifted to 0.2 below other cells. O2 flush at 6m & they only made it to 1.4. Once head dried out, they calibrated OK & worked OK for 90mins to 2 hours. Same problem we have encountered on the Classic. On long dives you get cells which begin to lag but not enough to set off a "cell warning" or maybe just very briefly now and again. No doubt from water droplets on the face of the cells. On a second dive in a day you can get the "must calibrate" if you've noticed cells become laggy. All cells will still reach 1.6 + in the above scenarios.When doing 2 dives, cell caused "must calibration" when unit turned on for 2nd dive rather than the more usual "calibrate?". However, more noticeable on longer 3 hour dives. One cell replaced by AP, the other is currently in my spares kit. Replacing cell fixed issue. Hope this helps JT Had a couple of cells over the last year begin to lag significantly. Wouldn't reach 1.4 on an o2 flush whilst the others did. They were about 8 months old. Turfed them and replaced. No problems. Figured they were current limited.
__________________ Cheers, Dave & Sandy ![]() Atvar shows Dave & Sandy testing their new habitat 101 and home build RBMK69's |
| (Offline) | |