Re: APD QC vs. Swagelok QC6

Quote: (Originally Posted by LukeN) View Original Post
If your look at the flow data on the QC6 it is really low (under 50l/min) I found them but wasn't game to trust my life on such a low flow rate.

I use snap tite svh-c4
Where did you get that flow value? There is only maximum flow rate for water given in Swagelok catalog and it is 22 L/min (water). Then we can make somekind of calculation or estimation how much for example TX15/55 can flow through it. My guess is a lot

Plazma, I have ordering numbers for you if you need them for QC6.