paulraymaekers has a brilliant future paulraymaekers has a brilliant future paulraymaekers has a brilliant future paulraymaekers has a brilliant future paulraymaekers has a brilliant future paulraymaekers has a brilliant future paulraymaekers has a brilliant future paulraymaekers has a brilliant future paulraymaekers has a brilliant future paulraymaekers has a brilliant future paulraymaekers has a brilliant future
Re: Submatix CCR 100 SMS

Quote: (Originally Posted by TR300) View Original Post
hmm,

the KISS-system automaticly (constant flow) add 0.8 l/min oxygen (+/- like the metabolism). you can add (if a failure occurs) manual some more oxygen.

on descend diluent is added manual or automaticly.

OK, by the eCCR (EN certfied) this is more controlled by an computer.

I think if the manufacteur describes this the certification should be no problem.

It should be interressting to get some information from an certification engeneer.

Holger
hello holger, if you go trough the 14143, for the testing of this spec, you have to set the breathing machine on different parameters of O2 consumption, and this goes from 0.4 l/min till 3 l/min

so at a flow setting of 0.8l/min, the gas will become hyperoxic very fast when at 0.4l/min consumption, and hypoxic at consumptions > 0.8l/min

regards
paul