Quote: (Originally Posted by ScubaDadMiami)
Gee, and I thought I was starting to remember the GF stuff. Because I went from U.S. Navy Tables straight to VPM, I never had more than an intellectual understanding of Buhlman related stuff over the years. Now, I have to start remembering how to apply it.
How about this: Request for ability to set last stop depth made hereby. When can I send in my handset for the upgrade?

Here is the way I suggest you handle it.., after clearing the 20fsw stop, note the time it says you need to stop at 10fsw, once this period has cleared proceed to 10fsw, and it should be clear or at least damn close.. I know in metric mode it clears correctly when the depth displays 3msw, but there is a delay clearing when in imperial mode and you are at 10fsw or deeper.. I know all the calcs are done in MSW then displayed in fsw, following this logic 10fsw is actuactly the next stop depth (for a truncated integer),
On an older revision (I havent tried it on the current sets) but I remember being at a "10 fsw" stop and just by moving my arm up and down to switch the display between 9 and 10 fsw I could get the 1 @10 to pop in and out..