Re: Question for Inspiration Classic users

Quote: (Originally Posted by decoweenie)
Just curious...

Has anyone seen the values differ between the handsets unless something drastically wrong ?
Last week my slave was displaying odd ppO2 values. Cells 2 and 3 were about 0.2 below set-point. The slave handset was also showing cell error, but the readings on master were all OK.

I tried to correct it by shutting down the handsets. Did not work and I think the reason was that I turned the master first off. I should have done it the other way.

Somehow the slave had wrong calibration values and when I started the other handset it took over the wrong ones.

Eventually I fixed the issue by calibrating again because I was still on the surface. The problem showed up during pre-breath on the surface.

JH
Finland