Quote: (Originally Posted by
louisrankin)

Hi Dave,
Are you using the same 02 supply for the orifice and soleniod? Is so what do you plan to use on deeper dives a second 02 bottle? Does the shearwater give you the functionality to turn of the soleniod is so desired?
Thanks in advance
Louis
Hi Louis, super simple as always: the 'plug'
with the kit we also supply a plug that you can mount on the exit of the orifice/non return valve
so less then 80m, fixed MP and no plug on the orifice
more then 80m: put the plug on the orifice, and take off the MP cap from the first stage... and you have a pure eCCR
takes you +/ ... 45 seconds??? :-)
paul
and even... suppose you are on a trip, and have a blocked open solenoid... well the plug also fits the exit of the solenoid, so in that case, just put the plug on the solenoid and you have a pure mCCR :-)