Re: Shearwater one-cell wireing to fisher??

Quote: (Originally Posted by johan carlsson) View Original Post
The questionmark is aboute what is wrong whith this picture??
I have one cell connected (is it wired wrong??)
The tre-cell indicators blinking?
Attachment 9274

Have tried to calibrate and i thaught that it would adjuste to one-cell reading on auto if onley one cell was connected? Is I wrong or are the wireing in the fischer contakt wrong?

Thanks. Johan
Hi Johan,
you must conect it to the "middle" cell.

I think you have a black cabel
So use GREEN for minus and GREY for positive if you connect only one cell.

Pining

Pin 1 -> grün/green/verde (Minus all sensors)
Pin 2 -> gelb/yellow/jaune
Pin 3 -> grau/grey/gris
Pin 4 -> rosa/pink


Any more questions? Hope this helps.