Quote: (Originally Posted by jiseson) View Original Post
the software fix cures the reboot sensor firing issue
Just to be clear... the software fix does not stop the rebooting (caused by the battery door issues, and/or low battery voltage, on the metal handset), it does greatly reduce the probability that the loop will become hyperoxic as a result of the rebooting. The diver will still lose all their decompression information, along with max depth and dive time on that handset, as a result of the reboot. The secondary will still have max depth and time, along with current depth, so that the diver can switch to a backup table.