ISC Information
great to see that ISC just posted A LOT of test data
including testing at 50m and 100m for 5 canister types
some APECS 2.5 Compliance Testing
and much more (including GOLEM BOV, HH electronics)
its great to see more and more data published
expect long discussions to start now...
I will strart:
how is it possible for the CISLunar radial canister to perform worse than the standard axial scrubber?
on the contrary the ExtendAir seems to be doing OK (better than the axial, worse than radial)
Its also important to note that the standars were a bit diferant than other testing. (75 RMV, 25bpm) so comparissions are not easy to make.
Question: doesnt EN specify RMV and BMM? Why each manufacturer is testing at diferant specs???
For GOLEM BOV owners (like me): I was surprised to see that it seems that the BOV fails the max WOB limit of 1,37