View Single Post
Old 14th February 2008, 03:48   #35 (permalink)
sensor330
Custom Title Allowed!
 
sensor330's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
Not Bought Yet
Inspiration Classic
 
Join Date: Feb 2005
Location: Victoria, British Columbia, Canada
Posts: 556
sensor330 is a jewel in the roughsensor330 is a jewel in the roughsensor330 is a jewel in the roughsensor330 is a jewel in the roughsensor330 is a jewel in the roughsensor330 is a jewel in the roughsensor330 is a jewel in the rough
Send a message via Yahoo to sensor330
Re: Meg cold diving - QC4 leak

Quote: (Originally Posted by jdicediver) View Original Post
The QC4 system on a Meg is NOT manufactured by Swagelok. The actual male quill made by Swagelok is somewhat different, being that the internal (pin) and collet are integral, not like the one ISC supplies as stock. I had problems with my male QC4 from new, and have since replaced it with the ACTUAL Swagelok item. The Male QC 4 from Swagelok is 100% interchangeable with the ISC item, and I have confirmed that the female connector need not be replaced to correct the leaking.
Be careful with the Swag item as I don't think they have gone through the passivation process. That's probably why ISC went with the QC4 they currently provide.

Scott
(Offline)
 
Reply With Quote