Quote: (Originally Posted by
paulraymaekers)

jean mi, I suppose your 3 read-outs are independant???
did not see you latest development, so...
what cells are you using? from the same batch, same age??
regards
paul
Hi paul,
i use r22's teledyne, same age less then 12 monthes all teste up to 2 bars in the tecme cell holder just before the dive as per usual, all wer lineral up to 2 bars
perfect sensors...I suspect the lumberg connector to have oxidize and ****ed the common ground...
from that time I've returned to potted cable glands as you advidesed me 5 years ago.. it works but the question is not rally there the question is why did I go on injecting seeing that after the first o2 injection the ppo2 had not jumped as it should have been... I always preach : don't inject without reading your sensors at the same time and track the rise of ppo2 to be sure that your sensor react normaly...and like the stupid guy then I am i've been able to inject looking at the display that did not move and to re-inject depite the obvious problem.... grrrrr
well
don(t know what to think about all of it...
the worst is to learn that a very good kiss diver died is similar conditions (as far as we know)...so it could happend to all of us...enven if I don't forgive myself to have has this stupid reaction I think that I won't be the la expérience kiss style diver to do that....
we are discussing a lot in our area with christian and other that you know
al those problem of sensor signal loss are making us think a lot...
well
regards
jean mi