| Re: Lights Out Quote: (Originally Posted by Drmike)  So just so I understand, there is a design fault in the switch which allows the magnet to fall out causing loss of power.
Both secondary and life supporting primary have same design fault in their switch (seeing as both switches are same design)
Hmmm, to me thats a little more than a 'little problem'
if one can fall out then both can fall out....if on the same dive it might be deadly at worse or mean you cant see any ppo2 display at best No.
The magnet can be pulled out during a battery change if the person is clumsy and breaks the glue that holds it in. The person then has to ignore this when they put it back together.