View Single Post
Old 31st October 2007, 10:04   #5 (permalink)
Ivon
Custom Title Allowed!
 
Ivon's Avatar

Current Rebreather/s:
Inspiration Classic

Other Rebreather/s:
 
Join Date: Feb 2006
Location: Hull, East Yorkshire, England
Posts: 318
Ivon has a spectacular aura aboutIvon has a spectacular aura aboutIvon has a spectacular aura aboutIvon has a spectacular aura aboutIvon has a spectacular aura aboutIvon has a spectacular aura about
Re: Offboard connection setup - Thoughts please?

Quote: (Originally Posted by Simon A) View Original Post
Womble,
It seems like you are adding a load of extra joints and making it over complicated.
You say you are using a BOV and offboard O2/Dil?
If so, I would consider something along the lines of:-
Onboard O2 plumbed into solenoid
Offboard O2 plumbed into O2 manual add.
Onboard Dil plumbed into ADV
Offboard Dil (bailout) plumbed into BOV

That gives you access to all your gases, the onboard O2 cylinder valve can be used to isolate the solenoid, the onboard Dil cylinder valve can be used to isolate the ADV and you have access to your bailout through the BOV without any restrictions that could give higher WOB at depth (high WOB is bad when trying to recover from a CO2 hit)

HTH
Simon A
Hey Pete,
This is the same set up as I use but without the BOV, just into the CL, it works for me.

Hope your good, you down at Chepstow next weekend?

Ivon.
(Offline)
 
Reply With Quote