Quote: (Originally Posted by Yankee Rebel) View Original Post
i think your RG-UF/M reg is supposed to flow at .8-1.1Lpm. so just timing how long it takes to fill your CL shouldnt be hard.

flow rate is .8 lpm for ease of example.. it takes 5 minutes 45 seconds to fill the CL from dead empty to firm/full... .8X5.75=4.6.
================
Nearly all RGUs I've handled, or heard of, seem to have a flow rate adjusted right at .9 l/m If you have a flowmeter, check this. Then use the method above. Assuming you have a DSV, then check it with DSV closed, and a charged scrubber in place. This will give you a total loop (excl man) free volume, a very useful number for several calculations.

Establishing such a method for 'time to fill the bag' also gives you a convenient quick-check method to verify correct mass flow pre-dive.