View Single Post
Old 19th July 2007, 10:52   #2 (permalink)
richc
New Member
 
richc's Avatar

Current Rebreather/s:
Ouroboros

Other Rebreather/s:
 
Join Date: Nov 2005
Location: Hove actually
Posts: 40
richc is an unknown quantity at this point
Re: Cool 900bars of Dil

Quote: (Originally Posted by CCR900) View Original Post
Anyone had problems with the HP pressure sensors, my dil is going a little bonkers 800+ bars. I need to sit down this weekend and check the connectors for water ingress but just wanted to know if it a one off.


Rgds

F
I had one go (O2 pressure sensor) during a week in Scapa. It goes a little crazy and doesn't hold a stable pressure. The most annoying thing was that the high usage alarm would come on when it jumped. If you need to dive it is possible to route a std pressure gauge from the first stage until you can replace it - the hose is a squeeze but definitely possible.

I sent the centre section to the factory for the work. In my case it was nothing to do with water ingress but a faulty component. Not CCRB's fault but they fixed it under warranty for me.

Rich
(Offline)
 