View Single Post
Old 12th July 2007, 10:34   #10 (permalink)
Lancer4545
Closed Circuit Divers Aus
 
Lancer4545's Avatar

Current Rebreather/s:
Megalodon

Other Rebreather/s:
 
Join Date: Jun 2007
Location: Cairns QLD Australia
Posts: 660
Lancer4545 is a jewel in the roughLancer4545 is a jewel in the roughLancer4545 is a jewel in the roughLancer4545 is a jewel in the roughLancer4545 is a jewel in the roughLancer4545 is a jewel in the roughLancer4545 is a jewel in the roughLancer4545 is a jewel in the rough
Send a message via Skype™ to Lancer4545
Re: Servicing Meg O2 & Dil Valves

Quote: (Originally Posted by jradomski) View Original Post
Did you remove the valve from the counterlung?? If not STOP and wait for your instructor.. If you have gone this far you might as well finish..

Its a standard ds addition valve.. the top portion (stationary base and rotating section) seperate from the securing base inside the cl.. The top 2 plastic sections were not designed to be taken apart!

next take off the isc logo and use a 2.5mm allen key on the metal button on top and a 4mm allen key on the stem inside.. now unscrew and pop the button off.. Clean, metal parts, change o-rings and relube.. screw back together, the install back on the counterlung..
Thankyou....

I have removed it because I found a part of the inside nut dangling around inside the counter lung. It would appear to be a baffle plate which is attached to the back of the nut. Somehow it has separated from the inner part which has the thread.

I did a quick check of the logo and thought it didn't have anything behind it. DOOOH

Thanks everyone for your help.

Regards,

Lance
(Offline)
 
Reply With Quote