Re: Cell Warning!

I've had a couple of cells that seemed to loose calibration on longer dives, drifted to 0.2 below other cells. O2 flush at 6m & they only made it to 1.4. Once head dried out, they calibrated OK & worked OK for 90mins to 2 hours.

When doing 2 dives, cell caused "must calibration" when unit turned on for 2nd dive rather than the more usual "calibrate?". However, more noticeable on longer 3 hour dives.

One cell replaced by AP, the other is currently in my spares kit.

Replacing cell fixed issue.

Hope this helps